3 QUALITY & INNOVATION SINCE 1907. WE CONSULT YOU INDIVIDUAL & PERSONALLY Since 1907 Kraus & Naimer focused on developing, manufacturing and distributing switches for low voltage applications. Only consequent specialization enables state of the art products on a highest technical quality level. The world’s first programmable cam switch already was branded with the Kraus & Naimer f. Today worldwide recognized and synonym for safe switching solutions and path braking innovation. In no time Kraus & Naimer emerged to the market leader of cam switches and is moreover one of the leading manufacturer for main disconnects. The wide and global oriented product portfolio OFFers a technical and economical optimized solution for nearly every application. Perfect service is the interface to our customers. Therefore we invest time and our long-term expertise in consulting you. Our team answers individually and competently your questions. On page 215 of our main catalog or our website www.krausnaimer.com you will find the contact persons of our branches worldwide.

4 More and more, the HMI is getting into the focus of end users and manufacturers – whether in building automation systems, general mechanical engineering or in special applications, such as the food and beverage processing industries. Our various product series with powerful devices and the latest software technology make it easy to get started with IoT/IIoT. Robust industrial standard products in a sophisticated design combining functionality and aesthetics. For more information, see page 6, 45, 88, 170 und 186.. Kraus & Naimer CONTROLS HUMAN MACHINE INTERFACE IoT Controller IoT Controller

G - Gewinde PG 7 PG 9 PG 11 PG 13,5 PG 16 PG 21 PG 29 PG 36 PG 42 PG 48 gebohrung 13 15,7 19 21 23 28,8 37,5 47,5 54,5 59,8 gebohrung 12,5 16,5 20,5 25,5 32,5 40,5 50,5 63,5 r. Gewinde M12 x 1,5 M16 x 1,5 M20 x 1,5 M25 x 1,5 M32 x 1,5 M40 x 1,5 M50 x 1,5 M63 x 1,5 Useful Information Push Buttons and Pilot Lights Main, Safety and Maintenance Switches Control Switches and Load Switches Switches for specific use and DC Switches www.krausnaimer.com 204 187 7 5 171 MAIN CATALOG 5 CONTENT < Click on the chapter to get there. >

6 Portrait and landscape screen orientation Ultra rugged M22 flunch and panel mounting HMI system single RJ45 CAT-5 PoE cable and USB port 10-years availability guarantee Field level installation HMI M22 Human Machine Interface (Exor International patent) Powerful CODESYS implementation Visualization screens in pure last generation web browser technology/ OPC-UA or JMobile software • TFT Superior optical performance • RGB color status LED • Black cover glass printing with minimal border • Rugged projective capacitive multitouch touch panel 3,2 mm thickness tempered glass • Contrast min. 500:1 • Web-Panel Kraus & Naimer CONTROLS The web-based powerful IoT panel for industry 4.0 KN-C 700 Plug & Play ultra thin design IP67 front fully sealed rugged construction Fastening nut stainless steel Standard RJ45 – IP20 Cat 5e shielded plug cable Additional: Shielded connector with straight or angle mounting available – IP67 Rugged M22 RJ45 stainless steel with thread locking Fully rugged enclosed metal housing aluminum Lighting Proximity Altitude Temperature Humidity 3-Axis accelerometer Integrated camera Advanced Diagnostic Optional: Sensors: 15 mm G L Optional: < Back to the catalog directory >

7 MAIN CATALOG  Main Switches  Safety Switches  Maintenance Switches < Back to the catalog directory Next >

USEFUL INFORMATION USEFUL INFO www.krausnaimer.com 8 MAIN CATALOG – Ordering example if a replacement is required – The most important data you should know about ordering, in case of replacement. 1. 2. If this information is not (completely) available, we will ask for meaningful photos. The variable block building system KG20-KG317 (not for KG10) 2. Auxiliary contact 1. Auxiliary contact PE terminal or or N-contact / N-terminal till KG162 till KG317 till KG317 till KG162 Cam- or rack-operated auxiliary contacts NO leading (off) or lagging (on) Cam- or rack-operated auxiliary contacts NO leading (off) or lagging (on) In general terms The terminals of KG10-KG160 are according to EN 50274, protected against direct contact according to BGV A3 and IP20 (up to size KG64). In the package content of the Main and Safety Switches, range KG80 to KG160 is one protective cover included and in the range from KG210 to KG315 there are two protective covers included. Labels from 2020 Labels until 2019 < Back to the catalog directory >

MAIN CATALOG 9 MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.de Complete items MAIN AND SAFETY SWITHCES Four hole panel mounting Single hole mounting 22 mm Base mounting and switch cabinet mounting with door clutch MAINTENANCE SWITCH Plastic enclosures For EMC-compliant connection Saftey switches Class 0 Stainless steel enclosures Aluminium enclosures ATEX Saftey switches Class 1 SWITCH DISCONNECTOR 3 pole Base mounting 45 mm standard knock-out, Four hole panel mounting, Single hole mounting 4 pole Double-throw switch Base mounting 45 mm standard knock-out POWER – 0 – EMERGENCY POWER Four hole panel mounting, Base mounting with shaft extension 1 – 0 – 2 Additional variations up to 8 contacts possible on inquiry! Accessory Solder joint terminals, Auxiliary contacts, PE- and N-Terminals, N-contacts, Cam or rack operated auxiliary switches, additional PE-/Nterminals for KS- and KL- enclosures, Refit kit EMC Protective covers, Terminals for control circuit, Connection aids Bolt terminals Accessory M700/., Accessory Single hole mounting, Mounting screws Add-on escutcheon plates for main switches Optional Extras for Customizing (available only in combination with a switch) Door clutch with four hole mounting (M280) for use in enclosures Padlock device with integrated door clutch for control door clutch (M700) for use in cabinets, Switch-side Padlock device according UL 508A Door clutch with Single hole mounting 22 mm, centering aid for plug-in door clutches Padlock device Switch Size Technical Data International Standards and Approvals 86 24 46 71 70 34 84 CHAPTER OVERVIEW 52 58 60 204 79 78 77 76 80 10 75 74 82 72 66 67 63 < Back to the catalog directory >

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 10 MAIN CATALOG Four hole panel mounting  2- and 3-pole, IP 66 Similar image 2-pole 3-pole T1 N L1 N L1 T1 L2 T2 L3 T3 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 M D1 M N D3 D2 P KG10A – KG64B A G L C max H R KG80 – KG315 A G L C max H R J L1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 2-pole 230 V 20 A 1,5 kW 48 x 48 KG10A.T202/01.E 64 x 64 KG10B.T202/01.E 3-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T203/01.E 64 x 64 KG10B.T203/01.E 25 A 7,5 kW 48 x 48 KG20A.T203/01.E 64 x 64 KG20B.T203/01.E 32 A 11 kW 48 x 48 KG32A.T203/01.E 64 x 64 KG32B.T203/01.E 40 A 15 kW 48 x 48 KG41.T203/01.E 64 x 64 KG41B.T203/01.E 63 A 22 kW 48 x 48 KG64.T203/01.E 64 x 64 KG64B.T203/01.E 80 A 30 kW 64 x 64 KG80.T203/01.E 88 x 88 KG80C.T203/01.E 100 A 37 kW 64 x 64 KG100.T203/01.E 88 x 88 KG100C.T203/01.E 125 A 45 kW 88 x 88 KG125.T203/01.E 160 A 55 kW 88 x 88 KG160.T203/01.E Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 2-pole 230 V 20 A 1,5 kW 48 x 48 KG10A.T102/01.E 64 x 64 KG10B.T102/01.E 3-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T103/01.E 64 x 64 KG10B.T103/01.E 25 A 7,5 kW 48 x 48 KG20A.T103/01.E 64 x 64 KG20B.T103/01.E 32 A 11 kW 48 x 48 KG32A.T103/01.E 64 x 64 KG32B.T103/01.E 40 A 15 kW 48 x 48 KG41.T103/01.E 64 x 64 KG41B.T103/01.E 63 A 22 kW 48 x 48 KG64.T103/01.E 64 x 64 KG64B.T103/01.E 80 A 30 kW 64 x 64 KG80.T103/01.E 88 x 88 KG80C.T103/01.E 100 A 37 kW 64 x 64 KG100.T103/01.E 88 x 88 KG100C.T103/01.E 125 A 45 kW 88 x 88 KG125.T103/01.E 160 A 55 kW 88 x 88 KG160.T103/01.E Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 4 2 8 1 64 x 64 9 3 88 x 88 10 3 Switch Drill hole pattern ACGHJ L L1R MN PD1D2D3 KG10A 2-pole 48 4 48 50 38,7 33 36 5 11-15 KG10A 3-pole 48 4 48 50 48,2 33 36 5 11-15 KG10B 2-pole 64 4 48 50 45,7 40,1 48 12,2 30 5 11-15 3,5 KG10B 3-pole 64 4 48 50 55,2 40,1 48 12,2 30 5 11-15 3,5 KG20A, KG32A 48 4 42 54 53,8 33 36 5 10-15 KG20B, KG32B 64 4 42 54 53,8 40,1 48 12,2 30 5 10-15 3,5 KG41, KG64 48 4 50 64 60,5 33 36 5 10-15 KG41B 64 4 50 64 60,5 40,1 48 12,2 30 5 10-15 3,5 KG64B 64 4 50 64 60,5 40,14814 375 10-154,5 KG80, KG100 64 4 70 80 5,5 70,6 26 40,1 48 14 37 5 10-15 4,5 KG80C, KG100C 88 4 70 80 5,5 70,6 26 49,3 68 14 37 6 10-15 4,5 KG125, KG160 88 5,5 112 108 96 22,2 49,3 68 6 13-17 Information about KG switches with bold terminals please see page 75. 2-/3-pole Complete items < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 11 MAIN CATALOG Four hole panel mounting  2- and 3-pole, IP 66 Similar image 2-pole 3-pole T1 N L1 N L1 T1 L2 T2 L3 T3 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 D1 D3 D2 P KG10A – KG64B A G L H R C max Q KG80 – KG315 A C max Q H L R J G L1 A C max Q H L R J G L1 C316 H A G R L L1 C max Q M12 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 88 x 88 9 4 130 x 130 9 4 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 2-pole 230 V 20 A 1,5 kW 48 x 48 KG10A.T202/04.E 64 x 64 KG10B.T202/04.E 3-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T203/04.E 64 x 64 KG10B.T203/04.E 25 A 7,5 kW 48 x 48 KG20A.T203/04.E 64 x 64 KG20B.T203/04.E 32 A 11 kW 48 x 48 KG32A.T203/04.E 64 x 64 KG32B.T203/04.E 40 A 15 kW 48 x 48 KG41.T203/04.E 64 x 64 KG41B.T203/04.E 63 A 22 kW 48 x 48 KG64.T203/04.E 64 x 64 KG64B.T203/04.E 80 A 30 kW 64 x 64 KG80.T203/04.E 88 x 88 KG80C.T203/04.E 100 A 37 kW 64 x 64 KG100.T203/04.E 88 x 88 KG100C.T203/04.E 125 A 45 kW 88 x 88 KG125.T203/04.E 160 A 55 kW 88 x 88 KG160.T203/04.E 200 A 75 kW 88 x 88 KG210.T203/05.E 250 A 90 kW 88 x 88 KG250.T203/05.E 315 A 110 kW 88 x 88 KG315.T203/05.E 315 A 132 kW 130 x 130 C316.T203/05.E 1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 2-pole 230 V 20 A 1,5 kW 48 x 48 KG10A.T102/04.E 64 x 64 KG10B.T102/04.E 3-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T103/04.E 64 x 64 KG10B.T103/04.E 25 A 7,5 kW 48 x 48 KG20A.T103/04.E 64 x 64 KG20B.T103/04.E 32 A 11 kW 48 x 48 KG32A.T103/04.E 64 x 64 KG32B.T103/04.E 40 A 15 kW 48 x 48 KG41.T103/04.E 64 x 64 KG41B.T103/04.E 63 A 22 kW 48 x 48 KG64.T103/04.E 64 x 64 KG64B.T103/04.E 80 A 30 kW 64 x 64 KG80.T103/04.E 88 x 88 KG80C.T103/04.E 100 A 37 kW 64 x 64 KG100.T103/04.E 88 x 88 KG100C.T103/04.E 125 A 45 kW 88 x 88 KG125.T103/04.E 160 A 55 kW 88 x 88 KG160.T103/04.E 200 A 75 kW 88 x 88 KG210.T103/05.E 250 A 90 kW 88 x 88 KG250.T103/05.E 315 A 110 kW 88 x 88 KG315.T103/05.E 315 A 132 kW 130 x 130 C316.T103/05.E 1 Switch Drill hole pattern ACGHJL L1 QRMN P D1D2 D3 KG10A 2-pole 48 4 48 50 38,7 7,2 51 36 12,2 30 5 11-15 3,5 KG10A 3-pole 48 4 48 50 48,2 7,2 51 36 12,2 30 5 11-15 3,5 KG10B 2-pole 64 4 48 50 45,7 8,1 58 48 5 11-15 KG10B 3-pole 64 4 48 50 55,2 8,1 58 48 5 11-15 KG20A, KG32A 48 4 42 54 53,8 7,2 51 36 12,2 30 5 10-15 3,5 KG20B, KG32B 64 4 42 54 53,8 8,1 58 48 5 10-15 KG41, KG64 48 4 50 64 60,5 7,2 51 36 5 10-15 KG41B 64 4 50 64 60,5 8,1 58 48 5 10-15 KG64B 64 4 50 64 60,5 8,158 4814 37 5 10-154,5 KG80, KG100 64 4 70 80 5,5 70,6 26 8,1 58 48 14 37 5 10-15 4,5 KG80C, KG100C 88 4 70 80 5,5 70,6 26 9 73 68 6 10-15 KG125, KG160 88 5,5 112 108 96 22,2 9 73 68 6 13-17 KG210, KG250 88 5,5 145 126 6 103 25 9 73 68 6 13-17 KG315 88 5,5 145 126 6 103 25 9 73 68 6 13-17 C316 130 7 128 150 117,2 46 9 86,5 104 7 16-20 1 Protection IP 40, enhanced protection degree On request Information about KG switches with bold terminals please see page 75. 2-/3-pole Complete items < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 12 MAIN CATALOG 4Fo-puor lheo, l3e-poalnee+l Nm+oPuEn,ti3n-gpole + 1 NO, IP 66  3 pole+1NO, IP 66 Similar image L1 T1 L2 T2 L3 T3 13 14 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 D1 N D3 D2 P KG10A – KG64B A G L C max H R KG80 – KG160 A G L C max H R J L1 A G L C max H R J L1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole +1NO 3 x 400 V 20 A 5,5 kW 48 x 48 64 x 64 KG10A.T203/17.E KG10B.T203/17.E 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T203/17.E KG20B.T203/17.E 32 A 11 kW 48 x 48 64 x 64 KG32A.T203/17.E KG32B.T203/17.E 40 A 15 kW 64 x 64 KG41B.T203/17.E 63 A 22 kW 64 x 64 KG64B.T203/17.E 80 A 30 kW 64 x 64 88 x 88 KG80.T203/17.E KG80C.T203/17.E 100 A 37 kW 64 x 64 88 x 88 KG100.T203/17.E KG100C.T203/17.E 125 A 45 kW 88 x 88 KG125.T203/17.E 160 A 55 kW 88 x 88 KG160.T203/17.E Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole +1NO 3 x 400 V 20 A 5,5 kW 48 x 48 64 x 64 KG10A.T103/17.E KG10B.T103/17.E 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T103/17.E KG20B.T103/17.E 32 A 11 kW 48 x 48 64 x 64 KG32A.T103/17.E KG32B.T103/17.E 40 A 15 kW 64 x 64 KG41B.T103/17.E 63 A 22 kW 64 x 64 KG64B.T103/17.E 80 A 30 kW 64 x 64 88 x 88 KG80.T103/17.E KG80C.T103/17.E 100 A 37 kW 64 x 64 88 x 88 KG100.T103/17.E KG100C.T103/17.E 125 A 45 kW 88 x 88 KG125.T103/17.E 160 A 55 kW 88 x 88 KG160.T103/17.E Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 4 2 8 1 64 x 64 9 3 88 x 88 10 3 Drill hole pattern M N P D1 D2 D3 KG10A 36 5 11-15 KG10B 48 12,2 30 5 11-15 3,5 KG20A, KG32A 36 5 10-15 KG20B, KG32B 48 12,2 30 5 10-15 3,5 KG41B 48 12,2 30 5 10-15 3,5 KG64B 48 14 37 5 10-15 4,5 KG80, KG100 48 14 37 5 10-15 4,5 KG80C, KG100C 68 14 37 6 10-15 4,5 KG125, KG160 68 6 13-17 Switch A C G H J L L1 R KG10A 48 4 48 50 48,2 33 KG10B 64 4 48 50 55,2 40,1 KG20A, KG32A 48 4 42 54 62,8 33 KG20B, KG32B 64 4 42 54 62,8 40,1 KG41B, KG64B 64 4 50 64 70,5 40,1 KG80, KG100 64 4 70 80 5,5 80,6 26 40,1 KG80C, KG100C 88 4 70 80 5,5 80,6 26 49,3 KG125, KG160 88 5,5 112 108 117 22,2 49,3 Information about KG switches with bold terminals please see page 75. 3-pole + 1NO Complete items < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 13 MAIN CATALOG 4Fo-puor lheo, l3e-poalnee+l Nm+oPuEn,ti3n-gpole + 1 NO, IP 66  3 pole+1NO, IP 66 Similar image KG C316 L1 T1 L2 T2 L3 T3 13 14 L1 T1 L2 T2 L3 T3 101 102 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 D1 N D3 D2 P KG10A – KG64B A G L H R C max Q KG80 – KG315 A C max Q H L R J G L1 A C max Q H L R J G L1 C316 H A G R L L1 C max Q M12 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 88 x 88 9 4 130 x 130 9 4 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole +1NO 3 x 400 V 20 A 5,5 kW 48 x 48 64 x 64 KG10A.T203/20.E KG10B.T203/20.E 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T203/20.E KG20B.T203/20.E 32 A 11 kW 48 x 48 64 x 64 KG32A.T203/20.E KG32B.T203/20.E 40 A 15 kW 64 x 64 KG41B.T203/20.E 63 A 22 kW 64 x 64 KG64B.T203/20.E 80 A 30 kW 64 x 64 88 x 88 KG80.T203/20.E KG80C.T203/20.E 100 A 37 kW 64 x 64 88 x 88 KG100.T203/20.E KG100C.T203/20.E 125 A 45 kW 88 x 88 KG125.T203/20.E 160 A 55 kW 88 x 88 KG160.T203/20.E 200 A 75 kW 88 x 88 KG210.T203/21.E 250 A 90 kW 88 x 88 KG250.T203/21.E 315 A 110 kW 88 x 88 KG315.T203/21.E 315 A 132 kW 130 x 130 C316.T203/21.E 1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole +1NO 3 x 400 V 20 A 5,5 kW 48 x 48 64 x 64 KG10A.T103/20.E KG10B.T103/20.E 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T103/20.E KG20B.T103/20.E 32 A 11 kW 48 x 48 64 x 64 KG32A.T103/20.E KG32B.T103/20.E 40 A 15 kW 64 x 64 KG41B.T103/20.E 63 A 22 kW 64 x 64 KG64B.T103/20.E 80 A 30 kW 64 x 64 88 x 88 KG80.T103/20.E KG80C.T103/20.E 100 A 37 kW 64 x 64 88 x 88 KG100.T103/20.E KG100C.T103/20.E 125 A 45 kW 88 x 88 KG125.T103/20.E 160 A 55 kW 88 x 88 KG160.T103/20.E 200 A 75 kW 88 x 88 KG210.T103/21.E 250 A 90 kW 88 x 88 KG250.T103/21.E 315 A 110 kW 88 x 88 KG315.T103/21.E 315 A 132 kW 130 x 130 C316.T103/21.E 1 Drill hole pattern M N P D1 D2 D3 KG10A 36 12,2 30 5 11-15 3,5 KG10B 48 5 11-15 KG20A, KG32A 36 12,2 30 5 10-15 3,5 KG20B, KG32B 48 5 10-15 KG41B 48 12,2 30 5 10-15 3,5 KG64B 48 14 37 5 10-15 4,5 KG80, KG100 48 14 37 5 10-15 4,5 KG80C, KG100C 68 6 10-15 KG125, KG160 68 6 13-17 KG210, KG250 68 6 13-17 KG315 68 6 13-17 C316 104 7 16-20 Switch A C G H J L L1 R Q KG10A 48 4 48 50 48,2 51 7,2 KG10B 64 4 48 50 55,2 58 8 KG20A, KG32A 48 4 42 54 62,8 51 7,2 KG20B, KG32B 64 4 42 54 62,8 58 8 KG41B, KG64B 64 4 50 64 70,5 58 8 KG80, KG100 64 4 70 80 5,5 80,6 26 58 8 KG80C, KG100C 88 4 70 80 5,5 80,6 26 73 9 KG125, KG160 88 5,5 112 108 117 22,2 73 9 KG210, KG250 88 5,5 145 126 6 124 25 73 9 KG315 88 5,5 145 126 6 124 25 73 9 C316 130 7 128 150 134,2 46 86,5 9,2 1 Protection IP 40, enhanced protection degree On request Information about KG switches with bold terminals please see page 75. 3-pole + 1NO Complete items < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 14 MAIN CATALOG 4Fo-puor lheo, l3e-poalnee+l Nm+oPuEn,ti3n-gpole + 1 NO, IP 66  3 pole+1NO + 1 NC, IP 66 Similar image L1 T1 L2 T2 L3 T3 31 32 43 44 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 D1 N D3 D2 P KG10A – KG64B A G L C max H R KG80 – KG160 A G L C max H R J L1 A G L C max H R J L1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole + 1NO +1NC 3 x 380 V/440 V 20 A 5,5 kW 64 x 64 KG10B.T203/A1.E 25 A 7,5 kW 64 x 64 KG20B.T203/A1.E 32 A 11 kW 64 x 64 KG32B.T203/A1.E 40 A 15 kW 64 x 64 KG41B.T203/A1.E 63 A 22 kW 64 x 64 KG64B.T203/A1.E 80 A 30 kW 64 x 64 88 x 88 KG80.T203/A1.E KG80C.T203/A1.E 100 A 37 kW 64 x 64 88 x 88 KG100.T203/A1.E KG100C.T203/A1.E 125 A 45 kW 88 x 88 KG125.T203/A1.E 160 A 55 kW 88 x 88 KG160.T203/A1.E Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole + 1NO +1NC 3 x 380 V/440 V 20 A 5,5 kW 64 x 64 KG10B.T103/A1.E 25 A 7,5 kW 64 x 64 KG20B.T103/A1.E 32 A 11 kW 64 x 64 KG32B.T103/A1.E 40 A 15 kW 64 x 64 KG41B.T103/A1.E 63 A 22 kW 64 x 64 KG64B.T103/A1.E 80 A 30 kW 64 x 64 88 x 88 KG80.T103/A1.E KG80C.T103/A1.E 100 A 37 kW 64 x 64 88 x 88 KG100.T103/A1.E KG100C.T103/A1.E 125 A 45 kW 88 x 88 KG125.T103/A1.E 160 A 55 kW 88 x 88 KG160.T103/A1.E Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 64 x 64 9 3 88 x 88 10 3 Drill hole pattern M N P D1 D2 D3 KG10B 48 12,2 30 5 11-15 3,5 KG20B, KG32B 48 12,2 30 5 10 3,5 KG41B 48 12,2 30 5 10 3,5 KG64B 48 14 37 5 10 3,5 KG80, KG100 48 14 37 5 10 4,5 KG80C, KG100C 68 14 37 6 10 4,5 KG125, KG160 68 6 13 Switch A C G H J L L1 R KG10B 64 4 48 50 55,2 40,1 KG20B, KG32B 64 4 42 54 53,8 40,1 KG41B, KG64B 64 4 50 64 60,5 40,1 KG80, KG100 64 4 70 80 5,5 70,6 26 40,1 KG80C, KG100C 88 4 70 80 5,5 70,6 26 49,3 KG125, KG160 88 5,5 112 108 96 22,2 49,3 Information about KG switches with bold terminals please see page 75. 3-pole + 1NO + 1 NC Complete items < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 15 MAIN CATALOG Four hole panel mounting  3 pole+1NO + 1 NC, IP 66 Similar image KG C316 L1 T1 L2 T2 L3 T3 31 32 43 44 L1 T1 L2 T2 L3 T3 103 104 101 102 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 D1 N D3 D2 P KG10A – KG64B A G L H R C max Q KG80 – KG315 A C max Q H L R J G L1 A C max Q H L R J G L1 C316 H A G R L L1 C max Q M12 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole + 1NO +1NC 3 x 380 V/440 V 20 A 5,5 kW 48 x 48 64 x 64 KG10A.T203/A2.E KG10B.T203/A2.E 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T203/A2.E KG20B.T203/A2.E 32 A 11 kW 48 x 48 64 x 64 KG32A.T203/A2.E KG32B.T203/A2.E 40 A 15 kW 64 x 64 KG41B.T203/A2.E 63 A 22 kW 64 x 64 KG64B.T203/A2.E 80 A 30 kW 64 x 64 88 x 88 KG80.T203/A2.E KG80C.T203/A2.E 100 A 37 kW 64 x 64 88 x 88 KG100.T203/A2.E KG100C.T203/A2.E 125 A 45 kW 88 x 88 KG125.T203/A2.E 160 A 55 kW 88 x 88 KG160.T203/A2.E 200 A 75 kW 88 x 88 KG210.T203/A3.E 250 A 90 kW 88 x 88 KG250.T203/A3.E 315 A 110 kW 88 x 88 KG315.T203/A3.E 315 A 132 kW 130 x 130 C316.T203/A3.E 1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole + 1NO +1NC 3 x 380 V/440 V 20 A 5,5 kW 48 x 48 64 x 64 KG10A.T103/A2.E KG10B.T103/A2.E 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T103/A2.E KG20B.T103/A2.E 32 A 11 kW 48 x 48 64 x 64 KG32A.T103/A2.E KG32B.T103/A2.E 40 A 15 kW 64 x 64 KG41B.T103/A2.E 63 A 22 kW 64 x 64 KG64B.T103/A2.E 80 A 30 kW 64 x 64 88 x 88 KG80.T103/A2.E KG80C.T103/A2.E 100 A 37 kW 64 x 64 88 x 88 KG100.T103/A2.E KG100C.T103/A2.E 125 A 45 kW 88 x 88 KG125.T103/A2.E 160 A 55 kW 88 x 88 KG160.T103/A2.E 200 A 75 kW 88 x 88 KG210.T103/A3.E 250 A 90 kW 88 x 88 KG250.T103/A3.E 315 A 110 kW 88 x 88 KG315.T103/A3.E 315 A 132 kW 130 x 130 C316.T103/A3.E 1 1 C316 Protection IP 44, enhanced protection degree on request Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 88 x 88 9 4 130 x 130 9 4 Drill hole pattern M N P D1 D2 D3 KG10B 48 12,2 30 5 11-15 3,5 KG20B, KG32B 48 12,2 30 5 10 3,5 KG41B 48 12,2 30 5 10 3,5 KG64B 48 14 37 5 10 4,5 KG80, KG100 48 14 37 5 10 4,5 KG80C, KG100C 68 14 37 6 10 4,5 KG125, KG160 68 6 13 KG210, KG250, KG315 68 6 13 C316 104 7 16 Switch A C G H J L L1 R Q KG10B 64 4 48 50 55,2 58 8 KG20B, KG32B 64 4 42 54 53,8 58 8 KG41B, KG64B 64 4 50 64 60,5 58 8 KG80, KG100 64 4 70 80 5,5 70,6 26 58 8 KG80C, KG100C 88 4 70 80 5,5 70,6 26 73 9 KG125, KG160 88 5,5 112 108 96 22,2 73 9 KG210, KG250, KG315 88 5,5 145 126 6 124 25 73 9 C316 130 7 128 150 134,2 46 86,5 9,2 Information about KG switches with bold terminals please see page 75. 3-pole + 1NO + 1 NC Complete items < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 16 MAIN CATALOG 3-pole + 1NO H-bridge Gold Complete items Four hole panel mounting  3-pole+1NO H-bridge Gold, IP 66 Similar image KG L1 T1 L2 T2 L3 T3 13 14 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 D1 N D3 D2 P KG20B – KG64B A G L C max H R KG80 – KG160 A G L C max H R J L1 A G L C max H R J L1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole 3 x 400 V 25 A 7,5 kW 64 x 64 KG20B.T203/D-A130.E 32 A 11 kW 64 x 64 On request 40 A 15 kW 64 x 64 On request 63 A 22 kW 64 x 64 On request 80 A 30 kW 64 x 64 KG80.T203/D-A133.E 88 x 88 On request 100 A 37 kW 64 x 64 On request 88 x 88 On request 125 A 45 kW 88 x 88 On request 160 A 55 kW 88 x 88 On request Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole 3 x 400 V 25 A 7,5 kW 64 x 64 On request 32 A 11 kW 64 x 64 On request 40 A 15 kW 64 x 64 On request 63 A 22 kW 64 x 64 On request 80 A 30 kW 64 x 64 KG80.T103/D-W020.E 88 x 88 On request 100 A 37 kW 64 x 64 KG100.T103/D-W020.E 88 x 88 KG100C .T103/D-A098.E 125 A 45 kW 88 x 88 On request 160 A 55 kW 88 x 88 KG160.T103/D-A076.E Notice: Highest contact reliability by H-bridge design with self-cleaning „cross-wire” contacts. Gold plated for low voltage, low current applications. Exception: KG20B and KG32B instead H-bridge design equipped with multiple connecting contacts. Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 64 x 64 9 3 88 x 88 10 3 Drill hole pattern M N P D1 D2 D3 KG20B, KG32B 48 12,2 30 5 10-15 3,5 KG41B 48 12,2 30 5 10-15 3,5 KG64B 48 14 37 5 10-15 4,5 KG80, KG100 48 14 37 5 10-15 4,5 KG80C, KG100C 68 14 37 6 10-15 4,5 KG125, KG160 68 6 13-17 Switch A C G H J L L1 R KG20B, KG32B 64 4 42 54 62,8 40,1 KG41B, KG64B 64 4 50 64 70,5 40,1 KG80, KG100 64 4 70 80 5,5 80,6 26 40,1 KG80C, KG100C 88 4 70 80 5,5 80,6 26 49,3 KG125, KG160 88 5,5 112 108 117 22,2 49,3 Information about KG switches with bold terminals please see page 75. < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 17 MAIN CATALOG Four hole panel mounting  3-pole+1NO H-bridge Gold, IP 66 Similar image KG C316 L1 T1 L2 T2 L3 T3 13 14 L1 T1 L2 T2 L3 T3 101 102 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 D1 N D3 D2 P KG20B – KG64B A G L H R C max Q KG80 – KG315 A C max Q H L R J G L1 A C max Q H L R J G L1 C316 H A G R L L1 C max Q M12 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 88 x 88 9 4 130 x 130 9 4 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole 3 x 400 V 25 A 7,5 kW 64 x 64 KG20B.T203/D-A288.E 32 A 11 kW 64 x 64 KG32B.T203/D-A190.E 40 A 15 kW 64 x 64 KG41B.T203/D-A076.E 63 A 22 kW 64 x 64 KG64B.T203/D-A044.E 80 A 30 kW 64 x 64 KG80.T203/D-A025.E 88 x 88 KG80C.T203/D-A026.E 100 A 37 kW 64 x 64 KG100.T203/D-A020.E 88 x 88 KG100C.T203/D-A021.E 125 A 45 kW 88 x 88 KG125.T203/D-A016.E 160 A 55 kW 88 x 88 KG160.T203/D-A014.E 200 A 75 kW 88 x 88 KG210.T203/D-A002.E 250 A 90 kW 88 x 88 KG250.T203/D-A006.E 315 A 110 kW 88 x 88 KG315.T203/D-A003.E 315 A 132 kW 130 x 130 C316.T203/D-A008.E 1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole 3 x 400 V 25 A 7,5 kW 64 x 64 KG20B.T103/D-A070.E 32 A 11 kW 64 x 64 KG32B.T103/D-A124.E 40 A 15 kW 64 x 64 KG41B.T103/D-A037.E 63 A 22 kW 64 x 64 KG64B.T103/D-A026.E 80 A 30 kW 64 x 64 KG80.T103/D-A017.E 88 x 88 KG80C.T103/D-A018.E 100 A 37 kW 64 x 64 KG100.T103/D-A012.E 88 x 88 KG100C.T103/D-A013.E 125 A 45 kW 88 x 88 KG125.T103/D-A010.E 160 A 55 kW 88 x 88 KG160.T103/D-A010.E 200 A 75 kW 88 x 88 KG210.T103/D-A001.E 250 A 90 kW 88 x 88 KG250.T103/D-A012.E 315 A 110 kW 88 x 88 KG315.T103/D-A008.E 315 A 132 kW 130 x 130 C316.T103/D-A010.E 1 Notice: Highest contact reliability by H-bridge design with self-cleaning „cross-wire” contacts. Gold plated for low voltage, low current applications. Exception: KG20B and KG32B instead H-bridge design equipped with multiple connecting contacts, C316 instead H-bridge Gold design equipped with connecting contacts. Drill hole pattern M N P D1 D2 D3 KG20B, KG32B 48 5 10-15 KG41B 48 12,2 30 5 10-15 3,5 KG64B 48 14 37 5 10-15 4,5 KG80, KG100 48 14 37 5 10-15 4,5 KG80C, KG100C 68 6 10-15 KG125, KG160 68 6 13-17 KG210, KG250 68 6 13-17 KG315 68 6 13-17 C316 104 7 16-20 Switch A C G H J L L1 R Q KG20B, KG32B 64 4 42 54 62,8 58 8 KG41B, KG64B 64 4 50 64 70,5 58 8 KG80, KG100 64 4 70 80 5,5 80,6 26 58 8 KG80C, KG100C 88 4 70 80 5,5 80,6 26 73 9 KG125, KG160 88 5,5 112 108 117 22,2 73 9 KG210, KG250 88 5,5 145 126 6 124 25 73 9 KG315 88 5,5 145 126 6 124 25 73 9 C316 130 7 128 150 134,2 46 86,5 9,2 1 Protection IP 40, enhanced protection degree on request Information about KG switches with bold terminals please see page 75. 3-pole + 1NO H-bridge Gold Complete items < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 18 MAIN CATALOG 4Fo-puor lheo, l3e-poalnee+l Nm+oPuEn,ti3n-gpole + 1 NO, IP 66  3-pole + N + PE, IP 66 Similar image L1 T1 L2 T2 L3 T3 PE PE N N 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 D1 N D3 D2 P KG20A – KG64B A G L C max H R G1 G1 KG80 – KG160 A G L L1 C max H R G1 G1 J A G L L1 C max H R G1 G1 J Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+N+PE 3 x 400 V 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T205/01.E KG20B.T205/01.E 32 A 11 kW 48 x 48 64 x 64 KG32A.T205/01.E KG32B.T205/01.E 40 A 15 kW 48 x 48 64 x 64 auf Anfrage KG41B.T205/01.E 63 A 22 kW 48 x 48 64 x 64 auf Anfrage KG64B.T205/01.E 80 A 30 kW 64 x 64 88 x 88 KG80.T205/01.E KG80C.T205/01.E 100 A 37 kW 64 x 64 88 x 88 KG100.T205/01.E KG100C.T205/01.E 125 A 45 kW 88 x 88 KG125.T205/01.E 160 A 55 kW 88 x 88 KG160.T205/01.E Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+N+PE 3 x 400 V 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T105/01.E KG20B.T105/01.E 32 A 11 kW 48 x 48 64 x 64 KG32A.T105/01.E KG32B.T105/01.E 40 A 15 kW 48 x 48 64 x 64 auf Anfrage KG41B.T105/01.E 63 A 22 kW 48 x 48 64 x 64 auf Anfrage KG64B.T105/01.E 80 A 30 kW 64 x 64 88 x 88 KG80.T105/01.E KG80C.T105/01.E 100 A 37 kW 64 x 64 88 x 88 KG100.T105/01.E KG100C.T105/01.E 125 A 45 kW 88 x 88 KG125.T105/01.E 160 A 55 kW 88 x 88 KG160.T105/01.E Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 4 2 8 1 64 x 64 9 3 88 x 88 10 3 Drill hole pattern M N P D1 D2 D3 KG20A, KG32A 36 5 10-15 KG20B, KG32B 48 12,2 30 5 10-15 3,5 KG41, KG64 36 5 10-15 KG41B 48 12,2 30 5 10-15 3,5 KG64B 48 14 37 5 10-15 4,5 KG80, KG100 48 14 37 5 10-15 4,5 KG80C, KG100C 68 14 37 6 10-15 4,5 KG125, KG160 68 6 13-17 Switch A C G G1 H J L L1 R KG20A, KG32A 48 4 42 13,5 54 53,8 33 KG20B, KG32B 64 4 42 13,5 54 53,8 40,1 KG41, KG64 48 4 50 16 64 60,5 33 KG41B, KG64B 64 4 50 16 64 60,5 40,1 KG80, KG100 64 4 70 22 80 5,5 70,6 26 40,1 KG80C, KG100C 88 4 70 22 80 5,5 70,6 26 49,3 KG125, KG160 88 5,5 112 38 108 96 22,2 49,3 Information about KG switches with bold terminals please see page 75. 3-pole + N + PE Complete items < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 19 MAIN CATALOG Four hole panel mounting  3-pole + N + PE, IP 66 Similar image L1 T1 L2 T2 L3 T3 PE PE N N 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 D1 N D3 D2 P KG20A – KG64B A G L H R C max Q G1 G1 KG80 – KG315 A G L L1 C max H R J Q G1 G1 A G L L1 C max H R J Q G1 G1 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 88 x 88 9 4 130 x 130 9 4 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole +N+PE 3 x 400 V 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T205/04.E KG20B.T205/04.E 32 A 11 kW 48 x 48 64 x 64 KG32A.T205/04.E KG32B.T205/04.E 40 A 15 kW 48 x 48 64 x 64 KG41.T205/04.E KG41B.T205/04.E 63 A 22 kW 48 x 48 64 x 64 KG64.T205/04.E KG64B.T205/04.E 80 A 30 kW 64 x 64 88 x 88 KG80.T205/04.E KG80C.T205/04.E 100 A 37 kW 64 x 64 88 x 88 KG100.T205/04.E KG100C.T205/04.E 125 A 45 kW 88 x 88 KG125.T205/04.E 160 A 55 kW 88 x 88 KG160.T205/04.E 200 A 75 kW 88 x 88 KG210.T205/05.E 250 A 90 kW 88 x 88 KG250.T205/05.E 315 A 110 kW 88 x 88 KG315.T205/05.E Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole +N+PE 3 x 400 V 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T105/04.E KG20B.T105/04.E 32 A 11 kW 48 x 48 64 x 64 KG32A.T105/04.E KG32B.T105/04.E 40 A 15 kW 48 x 48 64 x 64 KG41.T105/04.E KG41B.T105/04.E 63 A 22 kW 48 x 48 64 x 64 KG64.T105/04.E KG64B.T105/04.E 80 A 30 kW 64 x 64 88 x 88 KG80.T105/04.E KG80C.T105/04.E 100 A 37 kW 64 x 64 88 x 88 KG100.T105/04.E KG100C.T105/04.E 125 A 45 kW 88 x 88 KG125.T105/04.E 160 A 55 kW 88 x 88 KG160.T105/04.E 200 A 75 kW 88 x 88 KG210.T105/05.E 250 A 90 kW 88 x 88 KG250.T105/05.E 315 A 110 kW 88 x 88 KG315.T105/05.E Drill hole pattern M N P D1 D2 D3 KG20A, KG32A 36 12,2 30 5 10-15 3,5 KG20B, KG32B 48 5 10-15 KG41, KG64 36 5 10-15 KG41B 48 5 10-15 KG64B 48 14 37 5 10-15 4,5 KG80, KG100 48 14 37 5 10-15 4,5 KG80C, KG100C 68 6 10-15 KG125, KG160 68 6 13-17 KG210, KG250 68 6 13-17 KG315 68 6 13-17 Switch A C G G1 H J L L1 R Q KG20A, KG32A 48 4 42 13,5 54 53,8 51 7,2 KG20B, KG32B 64 4 42 13,5 54 53,8 58 8 KG41, KG64 48 4 50 16 64 60,5 51 7,2 KG41B, KG64B 64 4 50 16 64 60,5 58 8 KG80, KG100 64 4 70 22 80 5,5 70,6 26 58 8 KG80C, KG100C 88 4 70 22 80 5,5 70,6 26 73 9 KG125, KG160 88 5,5 112 38 108 96 22,2 73 9 KG210, KG250 88 5,5 145 126 6 124 25 73 9 KG315 88 5,5 145 126 6 124 25 73 9 Information about KG switches with bold terminals please see page 75. 3-pole + N + PE Complete items < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 20 MAIN CATALOG Four hole panel mounting  4-pole, IP 66 Similar image L1 T1 L2 T2 L3 T3 N N 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 M D1 M N D3 D2 P KG10A – KG64B A G L C max H R G1 KG80 – KG315 A G L C max H R G1 J L1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 4-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T204/01.E 64 x 64 KG10B.T204/01.E 25 A 7,5 kW 48 x 48 KG20A.T204/01.E 64 x 64 KG20B.T204/01.E 32 A 11 kW 48 x 48 KG32A.T204/01.E 64 x 64 KG32B.T204/01.E 40 A 15 kW 48 x 48 KG41.T204/01.E 64 x 64 KG41B.T204/01.E 63 A 22 kW 48 x 48 KG64.T204/01.E 64 x 64 KG64B.T204/01.E 80 A 30 kW 64 x 64 KG80.T204/01.E 88 x 88 KG80C.T204/01.E 100 A 37 kW 64 x 64 KG100.T204/01.E 88 x 88 KG100C.T204/01.E 125 A 45 kW 88 x 88 KG125.T204/01.E 160 A 55 kW 88 x 88 KG160.T204/01.E Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 4-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T104/01.E 64 x 64 KG10B.T104/01.E 25 A 7,5 kW 48 x 48 KG20A.T104/01.E 64 x 64 KG20B.T104/01.E 32 A 11 kW 48 x 48 KG32A.T104/01.E 64 x 64 KG32B.T104/01.E 40 A 15 kW 48 x 48 KG41.T104/01.E 64 x 64 KG41B.T104/01.E 63 A 22 kW 48 x 48 KG64.T104/01.E 64 x 64 KG64B.T104/01.E 80 A 30 kW 64 x 64 KG80.T104/01.E 88 x 88 KG80C.T104/01.E 100 A 37 kW 64 x 64 KG100.T104/01.E 88 x 88 KG100C.T104/01.E 125 A 45 kW 88 x 88 KG125.T104/01.E 160 A 55 kW 88 x 88 KG160.T104/01.E Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 4 2 8 1 64 x 64 9 3 88 x 88 10 3 Switch Drill hole pattern ACGG1H J L L1R MN P D1D2D3 KG10A 48 4 48 0 50 48,2 33 36 5 11-15 KG10B 64 4 48 0 50 55,2 40,1 48 12,2 30 5 11-15 3,5 KG20A, KG32A 48 4 42 13,5 54 53,8 33 36 5 10-15 KG20B, KG32B 64 4 42 13,5 54 53,8 40,1 48 12,2 30 5 10-15 3,5 KG41, KG64 48 4 50 16 64 60,5 33 36 5 10-15 KG41B 64 4 50 16 64 60,5 40,1 48 12,2 30 5 10-15 3,5 KG64B 64 4 50 16 64 60,5 40,1 48 14 37 5 10-15 4,5 KG80, KG100 64 4 70 22 80 5,5 70,6 26 40,1 48 14 37 5 10-15 4,5 KG80C, KG100C 88 4 70 22 80 5,5 70,6 26 49,3 68 14 37 6 10-15 4,5 KG125, KG160 88 5,5 112 38 108 96 22,2 49,3 68 6 13-17 Information about KG switches with bold terminals please see page 75. 4-pole Complete items < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 21 MAIN CATALOG Four hole panel mounting  4-pole, IP 66 Similar image L1 T1 L2 T2 L3 T3 N N 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 D1 D3 D2 P KG10A – KG64B A G L H R C max Q G1 KG80 – KG315 A L L1 C max H R J Q G G1 A L L1 C max H R J Q G G1 C316 H A G R L L1 C max Q M12 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 88 x 88 9 4 130 x 130 9 4 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 4-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T204/04.E 64 x 64 KG10B.T204/04.E 25 A 7,5 kW 48 x 48 KG20A.T204/04.E 64 x 64 KG20B.T204/04.E 32 A 11 kW 48 x 48 KG32A.T204/04.E 64 x 64 KG32B.T204/04.E 40 A 15 kW 48 x 48 KG41.T204/04.E 64 x 64 KG41B.T204/04.E 63 A 22 kW 48 x 48 KG64.T204/04.E 64 x 64 KG64B.T204/04.E 80 A 30 kW 64 x 64 KG80.T204/04.E 88 x 88 KG80C.T204/04.E 100 A 37 kW 64 x 64 KG100.T204/04.E 88 x 88 KG100C.T204/04.E 125 A 45 kW 88 x 88 KG125.T204/04.E 160 A 55 kW 88 x 88 KG160.T204/04.E 200 A 75 kW 88 x 88 KG210.T204/05.E 250 A 90 kW 88 x 88 KG250.T204/05.E 315 A 110 kW 88 x 88 KG315.T204/05.E 315 A 132 kW 130 x 130 C316.T204/05.E 1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 4-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T104/04.E 64 x 64 KG10B.T104/04.E 25 A 7,5 kW 48 x 48 KG20A.T104/04.E 64 x 64 KG20B.T104/04.E 32 A 11 kW 48 x 48 KG32A.T104/04.E 64 x 64 KG32B.T104/04.E 40 A 15 kW 48 x 48 KG41.T104/04.E 64 x 64 KG41B.T104/04.E 63 A 22 kW 48 x 48 KG64.T104/04.E 64 x 64 KG64B.T104/04.E 80 A 30 kW 64 x 64 KG80.T104/04.E 88 x 88 KG80C.T104/04.E 100 A 37 kW 64 x 64 KG100.T104/04.E 88 x 88 KG100C.T104/04.E 125 A 45 kW 88 x 88 KG125.T104/04.E 160 A 55 kW 88 x 88 KG160.T104/04.E 200 A 75 kW 88 x 88 KG210.T104/05.E 250 A 90 kW 88 x 88 KG250.T104/05.E 315 A 110 kW 88 x 88 KG315.T104/05.E 315 A 132 kW 130 x 130 C316.T104/05.E 1 Switch Drill hole pattern ACGG1HJL L1QR MN PD1D2 D3 KG10A 48 4 48 0 50 48,2 7,2 51 36 12,2 30 5 11-15 3,5 KG10B 64 4 48 0 50 55,2 8,1 58 48 5 11-15 KG20A, KG32A 48 4 42 13,554 53,8 7,2 51 36 12,2 30 5 10-15 3,5 KG20B, KG32B 64 4 42 13,554 53,8 8,1 58 48 5 10-15 KG41, KG64 48 4 50 16 64 60,5 7,2 51 36 5 10-15 KG41B 64 4 50 16 64 60,5 8,1 58 48 5 10-15 KG64B 64 4 50 16 64 60,5 8,1 58 48 14 37 5 10-15 4,5 KG80, KG100 64 4 70 22 80 5,5 70,6 26 8,1 58 48 14 37 5 10-15 4,5 KG80C, KG100C 88 4 70 22 80 5,5 70,6 26 9 73 68 6 10-15 KG125, KG160 88 5,5 112 38 108 96 22,2 9 73 68 6 13-17 KG210, KG250 88 5,5 145 52,5 126 6 103 25 9 73 68 6 13-17 KG315 88 5,5 145 52,5 126 6 103 25 9 73 68 6 13-17 C316 130 7 128 0 150 117,2 46 9 86,5 104 7 16-20 1 Protection IP 40, enhanced protection degree On request Information about KG switches with bold terminals please see page 75. 4-pole Complete items < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 22 MAIN CATALOG Four hole panel mounting  6-pole, IP 66 Similar image 1L1 1T1 1L2 1T2 1L3 1T3 2L1 2T1 2L2 2T2 2L3 2T3 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 M D1 M N D3 D2 P KG10B – KG64B KG10B – KG64B A G L C max H R C max G A F L KG80–KG160 C max L J H A L1 G C max L J H A L1 G Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 6-pole 3 x 400 V 20 A 5,5 kW 64 x 64 KG10B.T206/01.E 25 A 7,5 kW 64 x 64 KG20B.T206/01.E 32 A 11 kW 64 x 64 KG32B.T206/01.E 40 A 15 kW 64 x 64 KG41B.T206/01.E 63 A 22 kW 64 x 64 KG64B.T206/01.E 80 A 30 kW 64 x 64 KG80.T206/01.E 100 A 37 kW 64 x 64 KG100.T206/01.E 125 A 45 kW 88 x 88 KG125.T206/01.E 160 A 55 kW 88 x 88 KG160.T206/01.E Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 6-pole 3 x 400 V 20 A 5,5 kW 64 x 64 KG10B.T106/01.E 25 A 7,5 kW 64 x 64 KG20B.T106/01.E 32 A 11 kW 64 x 64 KG32B.T106/01.E 40 A 15 kW 64 x 64 KG41B.T106/01.E 63 A 22 kW 64 x 64 KG64B.T106/01.E 80 A 30 kW 64 x 64 KG80.T106/01.E 100 A 37 kW 64 x 64 KG100.T106/01.E 125 A 45 kW 88 x 88 KG125.T106/01.E 160 A 55 kW 88 x 88 KG160.T106/01.E Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 64 x 64 9 3 88 x 88 10 3 Switch Drill hole pattern ACGHJ L L1R MN PD1D2D3 KG10B 64 4 48 50 66,7 40,1 48 12,2 30 5 11-15 3,5 KG20B, KG32B 64 4 84 54 61,3 40,1 48 12,2 30 5 10-15 3,5 KG41B 64 4 100 64 66,5 40,1 48 12,2 30 5 10-15 3,5 KG64B 64 4 100 64 66,5 40,1 48 14 37 5 10-15 4,5 KG80, KG100 64 4 140 80 5,5 81,8 26 40,1 48 14 37 5 10-15 4,5 KG125, KG160 88 5,5 224 108 98 22,2 49,3 68 6 13-17 Information about KG switches with bold terminals please see page 75. 6-pole Complete items < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 23 MAIN CATALOG Four hole panel mounting  6-pole, IP 66 Similar image 1L1 1T1 1L2 1T2 1L3 1T3 2L1 2T1 2L2 2T2 2L3 2T3 4-hole (standard) 2-hole (alternative) possible if dimensions "N", "P" and "D3" are specified D2 M D1 M N D3 D2 P D2 D1 D3 D2 P KG10A – KG64B G F A L H R C max Q KG80 – KG315 C max L J H A L1 G R Q C max L J H A L1 G R Q Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 88 x 88 9 4 130 x 130 9 4 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 6-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T206/04.E 64 x 64 KG10B.T206/04.E 25 A 7,5 kW 64 x 64 KG20B.T206/04.E 32 A 11 kW 64 x 64 KG32B.T206/04.E 40 A 15 kW 64 x 64 KG41B.T206/04.E 63 A 22 kW 64 x 64 KG64B.T206/04.E 80 A 30 kW 64 x 64 KG80.T206/04.E 100 A 37 kW 64 x 64 KG100.T206/04.E 125 A 45 kW 88 x 88 KG125.T206/04.E 160 A 55 kW 88 x 88 KG160.T206/04.E Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 6-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T106/04.E 64 x 64 KG10B.T106/04.E 25 A 7,5 kW 64 x 64 KG20B.T106/04.E 32 A 11 kW 64 x 64 KG32B.T106/04.E 40 A 15 kW 64 x 64 KG41B.T106/04.E 63 A 22 kW 64 x 64 KG64B.T106/04.E 80 A 30 kW 64 x 64 KG80.T106/04.E 100 A 37 kW 64 x 64 KG100.T106/04.E 125 A 45 kW 88 x 88 KG125.T106/04.E 160 A 55 kW 88 x 88 KG160.T106/04.E Switch Drill hole pattern ACGHJL L1 QRMN P D1D2 D3 KG10A 48 4 48 50 57,7 7,2 51 36 12,2 30 5 11-15 3,5 KG10B 64 4 48 50 66,7 8,1 58 48 5 11-15 KG20B, KG32B 64 4 84 54 61,3 8,1 58 48 5 10-15 KG41B, KG64B 64 4 100 64 66,5 8,1 58 48 14 37 5 10-15 4,5 KG80, KG100 64 4 140 80 5,5 81,8 26 8,1 58 48 14 37 5 10-15 4,5 KG125, KG160 88 5,5 224 108 98 22,2 9 73 68 6 13-17 Information about KG switches with bold terminals please see page 75. 6-pole Complete items < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 24 MAIN CATALOG Single hole mounting 22 mm  2- und 3-pole, IP 66, IP 69k Similar image 2-pole 3-pole T1 N L1 N L1 T1 L2 T2 L3 T3 22,3+ 0,4 0 3,2+ 0,2 0 24,1+ 0,4 0 C max L G A H R Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 2-pole 230 V 20 A 1,5 kW 64 x 64 KG10B.T202/01.FT2 3-pole 3 x 400 V 20 A 5,5 kW 64 x 64 KG10B.T203/01.FT2 25 A 7,5 kW 64 x 64 KG20B.T203/01.FT2 32 A 11 kW 64 x 64 KG32B.T203/01.FT2 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 2-pole 230 V 20 A 1,5 kW 64 x 64 KG10B.T102/01.FT2 3-pole 3 x 400 V 20 A 5,5 kW 64 x 64 KG10B.T103/01.FT2 25 A 7,5 kW 64 x 64 KG20B.T103/01.FT2 32 A 11 kW 64 x 64 KG32B.T103/01.FT2 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 64 x 64 9 3 A L G H R C max KG10B 2-pole 64 64,4 48 50 40,1 6 KG10B 3-pole 64 73,9 48 50 40,1 6 KG20B 64 68,3 42 54 40,1 6 KG32B 64 68,3 42 54 40,1 6 2-/3-pole Complete items < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 25 MAIN CATALOG Single hole mounting 22 mm  2- und 3-pole, IP 66, IP 69k Similar image 2-pole 3-pole T1 N L1 N L1 T1 L2 T2 L3 T3 22,3+ 0,4 0 3,2+ 0,2 0 24,1+ 0,4 0 C max L G A H R Q Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 2-pole 230 V 20 A 1,5 kW 48 x 48 KG10A.T202/04.FT2 64 x 64 KG10B.T202/04.FT2 3-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T203/04.FT2 64 x 64 KG10B.T203/04.FT2 25 A 7,5 kW 48 x 48 KG20A.T203/04.FT2 64 x 64 KG20B.T203/04.FT2 32 A 11 kW 48 x 48 KG32A.T203/04.FT2 64 x 64 KG32B.T203/04.FT2 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 2-pole 230 V 20 A 1,5 kW 48 x 48 KG10A.T102/04.FT2 64 x 64 KG10B.T102/04.FT2 3-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T103/04.FT2 64 x 64 KG10B.T103/04.FT2 25 A 7,5 kW 48 x 48 KG20A.T103/04.FT2 64 x 64 KG20B.T103/04.FT2 32 A 11 kW 48 x 48 KG32A.T103/04.FT2 64 x 64 KG32B.T103/04.FT2 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 A L G H R Q C max KG10A 2-pole 48 57,4 48 50 52 7,2 6 KG10A 3-pole 48 66,9 48 50 52 7,2 6 KG10B 2-pole 64 64,4 48 50 58 8 6 KG10B 3-pole 64 73,9 48 50 58 8 6 KG20A, KG32A 48 68,3 42 54 52 7,2 6 KG20B, KG32B 64 68,3 42 54 58 8 6 2-/3-pole Complete items < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 26 MAIN CATALOG 4S i-npgolle ,h3o-l pe oml eo+uNn t+i nPgE ,232- pmoml e + 1 N O, I P 6 6  3-pole+1NO, IP 66, IP 69k Similar image L1 T1 L2 T2 L3 T3 13 14 22,3+ 0,4 0 3,2+ 0,2 0 24,1+ 0,4 0 C max L G A H R Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+1NO 3 x 400 V 20 A 5,5 kW 64 x 64 KG10B.T203/17.FT2 25 A 7,5 kW 64 x 64 KG20B.T203/17.FT2 32 A 11 kW 64 x 64 KG32B.T203/17.FT2 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+1NO 3 x 400 V 20 A 5,5 kW 64 x 64 KG10B.T103/17.FT2 25 A 7,5 kW 64 x 64 KG20B.T103/17.FT2 32 A 11 kW 64 x 64 KG32B.T103/17.FT2 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 4 2 8 1 64 x 64 9 3 A C G H L R KG10A 48 6 48 50 66,9 KG10B 64 6 48 50 73,9 40,1 KG20A, KG32A 48 6 42 54 77,3 KG20B, KG32B 64 6 42 54 77,3 40,1 3-pole + 1N O Complete items < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 27 MAIN CATALOG 3-pole + 1N O Complete items Single hole mounting 22 mm  3-pole+1NO, IP 66, IP 69k Similar image L1 T1 L2 T2 L3 T3 13 14 22,3+ 0,4 0 3,2+ 0,2 0 24,1+ 0,4 0 C max L G A H R Q Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+1NO 3 x 400 V 20 A 5,5 kW 48 x 48 64 x 64 KG10A.T203/20.FT2 KG10B.T203/20.FT2 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T203/20.FT2 KG20B.T203/20.FT2 32 A 11 kW 48 x 48 64 x 64 KG32A.T203/20.FT2 KG32B.T203/20.FT2 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+1NO 3 x 400 V 20 A 5,5 kW 48 x 48 64 x 64 KG10A.T103/20.FT2 KG10B.T103/20.FT2 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T103/20.FT2 KG20B.T103/20.FT2 32 A 11 kW 48 x 48 64 x 64 KG32A.T103/20.FT2 KG32B.T103/20.FT2 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 A C G H L R Q KG10A 48 6 48 50 66,9 51 7,2 KG10B 64 6 48 50 73,9 58 8 KG20A, KG32A 48 6 42 54 77,3 51 7,2 KG20B, KG32B 64 6 42 54 77,3 58 8 < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 28 MAIN CATALOG 4S i-npgolle ,h3o-l pe oml eo+uNn t+i nPgE ,232- pmoml e + 1 N O, I P 6 6  3-pole+1NO + 1 NC, IP 66 Similar image L1 T1 L2 T2 L3 T3 31 32 43 44 22,3+ 0,4 0 3,2+ 0,2 0 24,1+ 0,4 0 C max L G A H R Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+ 1NO +1NC 3 x 380 V/440 V 20 A 5,5 kW 64 x 64 KG10B.T203/A1.FT2 25 A 7,5 kW 64 x 64 KG20B.T203/A1.FT2 32 A 11 kW 64 x 64 KG32B.T203/A1.FT2 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+ 1NO +1NC 3 x 380 V/440 V 20 A 5,5 kW 64 x 64 KG10B.T103/A1.FT2 25 A 7,5 kW 64 x 64 KG20B.T103/A1.FT2 32 A 11 kW 64 x 64 KG32B.T103/A1.FT2 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 64 x 64 9 3 A C G H L R KG10B 64 6 48 50 75,6 40,1 KG20B, KG32B 64 6 42 54 77,3 40,1 3-pole + 1NO + 1 NC Complete items < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 29 MAIN CATALOG 3-pole + 1NO + 1 NC Complete items Single hole mounting 22 mm  3-pole+1NO + 1 NC, IP 66 Similar image L1 T1 L2 T2 L3 T3 31 32 43 44 22,3+ 0,4 0 3,2+ 0,2 0 24,1+ 0,4 0 C max L G A H R Q Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+ 1NO +1NC 3 x 380 V/440 V 20 A 5,5 kW 48 x 48 64 x 64 KG10A.T203/A2.FT2 KG10B.T203/A2.FT2 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T203/A2.FT2 KG20B.T203/A2.FT2 32 A 11 kW 48 x 48 64 x 64 KG32A.T203/A2.FT2 KG32B.T203/A2.FT2 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+ 1NO +1NC 3 x 380 V/440 V 20 A 5,5 kW 48 x 48 64 x 64 KG10A.T103/A2.FT2 KG10B.T103/A2.FT2 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T103/A2.FT2 KG20B.T103/A2.FT2 32 A 11 kW 48 x 48 64 x 64 KG32A.T103/A2.FT2 KG32B.T103/A2.FT2 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 A C G H L R Q KG10A 48 6 48 50 75,6 51 7,2 KG10B 64 6 48 50 75,6 58 8 KG20A, KG32A 48 6 42 54 77,3 51 7,2 KG20B, KG32B 64 6 42 54 77,3 58 8 < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 30 MAIN CATALOG 4S i-npgolle ,h3o-l pe oml eo+uNn t+i nPgE ,232- pmoml e + 1 N O, I P 6 6  3-pole+N+PE, IP 66, IP 69k Similar image L1 T1 L2 T2 L3 T3 PE PE N N 22,3+ 0,4 0 3,2+ 0,2 0 24,1+ 0,4 0 C max L G A H R G1 G1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+N+PE 3 x 400 V 25 A 7,5 kW 64 x 64 KG20B.T205/01.FT2 32 A 11 kW 64 x 64 KG32B.T205/01.FT2 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+N+PE 3 x 400 V 25 A 7,5 kW 64 x 64 KG20B.T105/01.FT2 32 A 11 kW 64 x 64 KG32B.T105/01.FT2 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 4 2 8 1 64 x 64 9 3 A C G G1 H L R KG20A, KG32A 48 6 42 13,5 54 68,3 KG20B, KG32B 64 6 42 13,5 54 68,3 40,1 3-pole + N + PE Complete items < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 31 MAIN CATALOG 3-pole + N + PE Complete items Single hole mounting 22 mm  3-pole+N+PE, IP 66, IP 69k Similar image L1 T1 L2 T2 L3 T3 PE PE N N 22,3+ 0,4 0 3,2+ 0,2 0 24,1+ 0,4 0 C max L G A H R Q G1 G1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+N+PE 3 x 400 V 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T205/04.FT2 KG20B.T205/04.FT2 32 A 11 kW 48 x 48 64 x 64 KG32A.T205/04.FT2 KG32B.T205/04.FT2 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole+N+PE 3 x 400 V 25 A 7,5 kW 48 x 48 64 x 64 KG20A.T105/04.FT2 KG20B.T105/04.FT2 32 A 11 kW 48 x 48 64 x 64 KG32A.T105/04.FT2 KG32B.T105/04.FT2 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 A C G G1 H L R Q KG20A, KG32A 48 6 42 13,5 54 68,3 51 7,2 KG20B, KG32B 64 6 42 13,5 54 68,3 58 8 < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 32 MAIN CATALOG Single hole mounting 22 mm  4-pole, IP 66, IP 69k Similar image L1 T1 L2 T2 L3 T3 N N 22,3+ 0,4 0 3,2+ 0,2 0 24,1+ 0,4 0 C max L G A H R G1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 4-pole 3 x 400 V 20 A 5,5 kW 64 x 64 KG10B.T204/01.FT2 25 A 7,5 kW 64 x 64 KG20B.T204/01.FT2 32 A 11 kW 64 x 64 KG32B.T204/01.FT2 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 4-pole 3 x 400 V 20 A 5,5 kW 64 x 64 KG10B.T104/01.FT2 25 A 7,5 kW 64 x 64 KG20B.T104/01.FT2 32 A 11 kW 64 x 64 KG32B.T104/01.FT2 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 64 x 64 9 3 A L G G1 H R C max KG10B 64 73,9 48 0 50 40,1 6 KG20B 64 68,3 42 13,5 54 40,1 6 KG32B 64 68,3 42 13,5 54 40,1 6 4-pole Complete items < Back to the catalog directory

www.krausnaimer.com MAIN, SAFETY AND MAINTENANCE SWITCH 33 MAIN CATALOG Single hole mounting 22 mm  4-pole, IP 66, IP 69k Similar image L1 T1 L2 T2 L3 T3 N N 22,3+ 0,4 0 3,2+ 0,2 0 24,1+ 0,4 0 C max L G A H R Q G1 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 4-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T204/04.FT2 64 x 64 KG10B.T204/04.FT2 25 A 7,5 kW 48 x 48 KG20A.T204/04.FT2 64 x 64 KG20B.T204/04.FT2 32 A 11 kW 48 x 48 KG32A.T204/04.FT2 64 x 64 KG32B.T204/04.FT2 Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 4-pole 3 x 400 V 20 A 5,5 kW 48 x 48 KG10A.T104/04.FT2 64 x 64 KG10B.T104/04.FT2 25 A 7,5 kW 48 x 48 KG20A.T104/04.FT2 64 x 64 KG20B.T104/04.FT2 32 A 11 kW 48 x 48 KG32A.T104/04.FT2 64 x 64 KG32B.T104/04.FT2 Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 48 x 48 7 3 5 4 64 x 64 8 3 5 4 A L G G1H R Q Cmax KG10A 48 66,9 48 0 50 52 7,2 6 KG10B 64 73,9 48 0 50 58 8 6 KG20A, KG32A 48 68,3 42 13,5 54 52 7,2 6 KG20B, KG32B 64 68,3 42 13,5 54 58 8 6 4-pole Complete items < Back to the catalog directory

MAIN, SAFETY AND MAINTENANCE SWITCH www.krausnaimer.com 34 MAIN CATALOG Intergrated door clutch for enclosures  3-pole, IP 66/67 Similar image L1 T1 L2 T2 L3 T3 Drill hole pattern face plate up to KG100 KG125 – KG160 19-22 48 5 26-30 68 6 Drill hole pattern base (mounting on DIN rail up to KG100) KG10B KG20B – KG100 KG125 – KG160 50 4,1 65 4,1 60 4,2 22 P N D3 P N D3 KG10B – KG64B L max C max G H L1 R A KG80 – KG160 L max C max H G L1 R A Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole 3 x 400 V 20 A 5,5 kW 64 x 64 KG10B.T203/09.VE 25 A 7,5 kW 64 x 64 KG20B.T203/09.VE 32 A 11 kW 64 x 64 KG32B.T203/09.VE 40 A 15 kW 64 x 64 KG41B.T203/09.VE 63 A 22 kW 64 x 64 KG64B.T203/09.VE 80 A 30 kW 64 x 64 KG80.T203/09.VE 100 A 37 kW 64 x 64 KG100.T203/09.VE 125 A 45 kW 88 x 88 KG125.T203/09.VE 160 A 55 kW 88 x 88 KG160.T203/09.VE Thermal current (Iu/Ith) Rating AC-23B (A) Face plate Order number 3-pole 3 x 400 V 20 A 5,5 kW 64 x 64 KG10B.T103/09.VE 25 A 7,5 kW 64 x 64 KG20B.T103/09.VE 32 A 11 kW 64 x 64 KG32B.T103/09.VE 40 A 15 kW 64 x 64 KG41B.T103/09.VE 63 A 22 kW 64 x 64 KG64B.T103/09.VE 80 A 30 kW 64 x 64 KG80.T103/09.VE 100 A 37 kW 64 x 64 KG100.T103/09.VE 125 A 45 kW 88 x 88 KG125.T103/09.VE 160 A 55 kW 88 x 88 KG160.T103/09.VE Maximum number of padlocks Face plate Shackle-Ø Number of padlocks 64 x 64 9 3 88 x 88 10 3 N P D3 KG20B, KG32B 22 60 4,1 KG41B, KG64B 25 70 4,1 KG80, KG100 25 90 5,2 KG125, KG160 36 120 6,4 A C G H L L1 R KG10B 64 4 48 50 190 40,1 KG20B, KG32B 64 4 42 54 190 40,1 KG41B 64 4 50 64 190 40,1 KG64B 64 4 50 64 330 40,1 KG80 64 4 70 80 380 26 40,1 KG100 64 4 70 80 450 26 40,1 KG125, KG160 88 5,5 112 108 450 22,2 49,3 Information about KG switches with bold terminals please see page 75. 3-pole Complete items < Back to the catalog directory