COM/DAT User Manual

User Manual 28 < back to the table of contents > 7.4 Diagnostics The diagnostic data provides an overview of the status of the selected DAT-Module. Explanations of the diagnostic data can be found in Table 10. T Table 10: Explanation of the diagnostic data of the DAT-Module. Name Explanation Name Explanation Sequence Sequential number of the diagnostic record. Energy lifetime Phase 2 exported Energy in kWh exported on phase L2 over the entire lifetime. Version Version of the diagnostic data format. Energy lifetime Phase 3 imported Energy in kWh imported on phase L3 over the entire lifetime. Highest system tick counter Upper 32 bits of the system tick counter. Energy lifetime Phase 3 exported Energy in kWh exported on phase L3 over the entire lifetime. Lowest system tick counter Lower 32 bits of the system tick counter. Energy trip Phase 1 imported Energy in kWh imported on phase L1 since the last reset (diagnostic reset, factory reset). System flags BMM_STATE_FL_PERIODIC 0x10 → Diagnostic record written periodically BMM_STATE_FL_POWEROUT 0x20 → Diagnostic record written due to power outage BMM_STATE_FL_REBOOT 0x40 → Diagnostic record written due to reboot Energie-Trip Phase 1 Exportiert Energy in kWh exported on phase L1 since the last reset (diagnostic reset, factory reset). MKM14 Sample count Number of measured value records collected since module start/reset. Energy trip Phase 2 imported Energy in kWh imported on phase L2 since the last reset (diagnostic reset, factory reset). MKM14 Error count Number of communication errors with the co-­ processor since module start/reset. A certain number of errors is considered normal, as communication must be synchronized after startup or switching from maintenance to measurement mode. Energy trip Phase 2 exported Energy in kWh exported on phase L2 since the last reset (diagnostic reset, factory reset). Runtime Total runtime of the module since manufacturing, in seconds. Energy trip Phase 3 imported Energy in kWh imported on phase L3 since the last reset (diagnostic reset, factory reset). Runtime below 50 °C Runtime of the module since manufacturing, in seconds, within a temperature range below 50 °C. Based on processor temperature. Energy trip Phase 3 exported Energy in kWh exported on phase L3 since the last reset (diagnostic reset, factory reset). Runtime between 50 °C and 70 °C Runtime of the module since manufacturing, in seconds, within a temperature range between 50 °C and 70 °C. Based on processor temperature. Minimum temperature Lowest processor temperature recorded over the entire lifetime. Runtime between 70 °C and 90 °C Runtime of the module since manufacturing, in seconds, within a temperature range between 70 °C and 90 °C. Based on processor temperature. Maximum temperature Highest processor temperature recorded over the entire lifetime. Runtime between 90 °C and 110 °C Runtime of the module since manufacturing, in seconds, within a temperature range between 90 °C and 110 °C. Based on processor temperature. Maximum current Highest current recorded over the entire lifetime. Runtime above 110 °C Runtime of the module since manufacturing, in seconds, within a temperature range above 110 °C. Based on processor temperature. Maximum voltage Highest voltage recorded over the entire lifetime. Energy lifetime Phase 1 imported Energy in kWh imported on phase L1 over the entire lifetime. K32 firmware version Software version and build date of the communication processor. Energy lifetime Phase 1 exported Energy in kWh exported on phase L1 over the entire lifetime. MKM14 firmware version Software version and build date of the measurement processor. Energy lifetime Phase 2 imported Energy in kWh imported on phase L2 over the entire lifetime.

RkJQdWJsaXNoZXIy MTAxNzE=