47 Cam Switches low voltage systems Low Voltage and Electronic Cicuit Switches from 30mV * For Voltage values less than 1 Volt please contact Kraus & Naimer Kraus & Naimer Rotary CAM Switches For Low Voltage Systems, Minimum and Maximum Ratings Contact reliability depends on various parameters such as the number of operations per day, maximum permissible contact resistance, environmental conditions (dust, chemical contamination of the ambient air) and others. 1. Ambient air is free of particular contamination with sulphur and/or sulphurous components such as H2S etc. 2. Ambient air may be contaminated with sulfur and/or sulphurous compound 3. In the case of extraordinary contamination with dust and adequate dust, protection is required Rigid Double Break Bridge Used in: CA10, CA10-1 and CG8 Multi Cross-Point Used in: CA4, CA4-1, CG4 and CG4-1 H-Bridge Cross-Wire Used in: CAD11 and CAD12 We recommend the use of K&N specialist switches for low voltage 4-20 mA applications SWITCH TYPE MINIMUM MAXIMUM MINIMUM MAXIMUM VOLTAGE VOLTAGE CURRENT CURRENT CONTACT CONTACT V V mA A SYSTEM MATERIAL 20 440 5 10 Multi Cross-Point Silver Alloy 12 440 3 10 Multi Cross-Point Gold Alloy 20 690 5 20 Rigid Double Break Bridge Silver Alloy 20 690 3 20 Rigid Double Break Bridge Gold Alloy 1 * 600 1 6 H-Bridge Cross-Wire Gold Alloy 6 600 2 6 H-Bridge Cross-Wire Silver Alloy 20 440 5 10 Multi Cross-Point Silver Alloy 12 440 3 10 Multi Cross-Point Gold Alloy 20 690 5 20 Rigid Double Break Bridge Silver Alloy CA4 CA4-1 CA10 CG10-1 CAD11 CAD12 CG4 CG4-1 CG8 Contact Systems