KRAUS & NAIMER Enclosed Product Catalogue
14 www.krausnaimer.ie Main/Emergency-Off Switch - 3, 4, & 6 Pole 25A - 315A Ie AC-21A 3 Pole 3 Pole + Solid Neutral (TP&N) 4 Pole (3ph + Sw N 2 ) 25A KG20 T203/GB20U2 *GP1 KG20 T207/GB20U2 *GP1 KG20 T204/GB20U2 *GP1 32A KG32 T203/GB20U2 *GP1 KG32 T207/GB20U2 *GP1 KG32 T204/GB20U2 *GP1 40A KG41 T203/GB20U2 *GP1 KG41 T207/GB20U2 *GP1 KG41 T204/GB20U2 *GP1 63A KG64 T203/GB20U2 *GP1 KG64 T207/GB20U2 *GP1 KG64 T204/GB20U2 *GP1 80A KG80 T203/GB20U2 *GP1 KG80 T207/GB20U2 *GP1 KG80 T204/GB20U2 *GP1 100A KG100 T203/GB20U2 *GP1 KG100 T207/GB20U2 *GP1 KG100 T204/GB20U2 *GP1 125A KG105 T203/GB20U2 *GP1 KG105 T207/GB20U2 *GP1 KG105 T204/GB20U2 *GP1 125A 3) KG125 T203/GB22T2 *GP6 KG125 T207/GB22T2 *GP6 KG125 T204/GB22T2 *GP6 160A KG160 T203/GB22T2 *GP6 KG160 T207/GB22T2 *GP6 KG160 T204/GB22T2 *GP6 200A KG210 T203/GB22T1 *GP6 KG210 T207/GB22T1 *GP6 KG210 T204/GB22T1 *GP6 250A KG250 T203/GB22T1 *GP6 KG250 T207/GB22T1 *GP6 KG250 T204/GB22T1 *GP6 315A KG315 T203/GB22T1 *GP6 KG315 T207/GB22T1 *GP6 KG315 T204/GB22T1 *GP6 Ie AC-21A 3 Pole 3 Pole + Solid Neutral (TP&N) 4 Pole (3ph + Sw N 2 ) 25A KG20 T203/GB00U2 *GP1 KG20 T207/GB00U2 *GP1 KG20 T204/GB00U2 *GP1 32A KG32 T203/GB00U2 *GP1 KG32 T207/GB00U2 *GP1 KG32 T204/GB00U2 *GP1 40A KG41 T203/GB00U2 *GP1 KG41 T207/GB00U2 *GP1 KG41 T204/GB00U2 *GP1 63A KG64 T203/GB00U2 *GP1 KG64 T207/GB00U2 *GP1 KG64 T204/GB00U2 *GP1 80A KG80 T203/GB00U2 *GP1 KG80 T207/GB00U2 *GP1 KG80 T204/GB00U2 *GP1 100A KG100 T203/GB00U2 *GP1 KG100 T207/GB00U2 *GP1 KG100 T204/GB00U2 *GP1 125A KG105 T203/GB00U2 *GP1 KG105 T207/GB00U2 *GP1 KG105 T204/GB00U2 *GP1 125A 3) KG125 T203/GB00T2 *GP6 KG125 T207/GB00T2 *GP6 KG125 T204/GB00T2 *GP6 160A KG160 T203/GB00T2 *GP6 KG160 T207/GB00T2 *GP6 KG160 T204/GB00T2 *GP6 200A KG210 T203/GB00T1 *GP6 KG210 T207/GB00T1 *GP6 KG210 T204/GB00T1 *GP6 250A KG250 T203/GB00T1 *GP6 KG250 T207/GB00T1 *GP6 KG250 T204/GB00T1 *GP6 315A KG315 T203/GB00T1 *GP6 KG315 T207/GB00T1 *GP6 KG315 T204/GB00T1 *GP6 GP6 GP3 GP1 • IP66 protection • red/yellow padlockable handle • optional black handle available • GRP enclosure, grey RAL7035 • earth terminal included • switch interlocked with lid to prevent opening in ‘ON’ position OFF-ON / SWITCH DISCONNECTORS Without Auxiliaries With Auxiliaries 1 Notes 1) The following auxiliary contacts are provided:- KG20 to KG105 2 N.O. (early break) KG125 to KG315 2 N.O. (early break) + 2 N.C. 2) Switched neutral pole is early make/late break. 3) KG125 suitable for applications requiring larger cable termination and increased enclosure size. 4) GP1 enclosures have only 1 quarter turn lock, GP3 & GP6 enclosures have 2 quarter turn locks. 5) Dimensions ‘D’ and ‘E’ show the position for drilling internal fixing holes. External mounting brackets, which can be fixed either horizontally or vertically, are also available as an optional extra. See Part No. UK 08-0412 on facing page.
Made with FlippingBook
RkJQdWJsaXNoZXIy MTAxNzE=