4 IEC 60947-3 SWITCHES - DISCONNECTORS - SWITCH DISCONNECTORS IEC 60947 is a safety and performance standard for low voltage switchgear (up to 1000V) which has universally replaced IEC 408 and combined specific requirements of many individual national standards. IEC 60947 is a uniform standard for most countries around the world and establishes a truely global marketplace. IEC 60947-3 is a section of the standard specific to switches. Importantly, it recognises that devices for the switching function and isolating function require very different perform- ance criteria. Switching requires high performance of current carrying parts to make and break loads under normal and overload conditions, ie., motor reversing applications. Isolation requires high insulation, sufficient spacing of current carrying parts and mechanical integrity that the handle corresponds to actual contact position for the safety of maintenance personnel. Practicality of real life applications calls for three definitions within IEC 60947-3; Switches, Disconnectors and Switch Disconnec- tors. A switch does not have to satisfy the isolation and mechanical strength tests, and a disconnector likewise the load tests. A Switch Disconnector must satisfy all tests and is suitable for safety switch applications. A switch disconnector must have a direct drive late make early break auxillary contact in series with a load breaking device to be suitable as a safety switch. Kraus & Naimer have developed complete products which satisfy all IEC 60947 criteria, some of which are listed overleaf. For further information, please contact our offices. FOR HIGHER CURRENT RATINGS Please contact your nearest KRAUS & NAIMER stockist. SWITCH RATINGS KG10 690 20 5.5 100 20 2.5 KG20 690 25 7.5 110 35 6 KG32 690 32 11 168 35 6 KG41 690 40 15 220 50 16 KG64 690 63 22 320 63 16 KG80 690 80 30 425 80 50 KG100 690 100 37 520 100 50 KG105 690 125 45 600 125 50 KG126 1000(1) 125 45 600 125 95(2) KG161 1000(1) 160 55 660 160 95(2) KG211 1000(1) 200 75 760 200 185(2) KG251 1000(1) 250 90 900 250 185(2) KG316 1000(1) 315 110 1200 315 185(2) KH16 800(1) 16 7.5 110 25 6 KH25 800(1) 25 12 170 35 6 KH32 800(1) 32 16 225 35 10 KH40 800(1) 40 20 265 50 10 KH63 1000(1) 63 30 425 80 35 KH80 1000(1) 80 40 505 100 35 6KE252 800(1) 250 132 2000 250 150(2) 6KE401 1000(1) 400 220 3200 400 240(2) 6KE631 1000(1) 630 280 3200 630 2x300(2) 6KE801 1000(1) 800 425 6400 800 2x300(2) 6KE1251 1000(1) 1250 530 8000 1250 4x185(2) (1) Suitable for no-load switching applications (AC-20A) above 690V (2) Denotes lugged terminal Switch Rated Resistive Motor Load "M" Rating Max Fuse Size Max Wire Gauge Type Insulation Load Switching Locked (gl characteristic) To suit terminal size Voltage Switching AC23A/415V Rotor For Short Circuit and rating U i AC21A Protection Volt Amp kW Amp Amp mm 2

RkJQdWJsaXNoZXIy MTAxNzE=