KRAUS & NAIMER Main Switches and Maintenance Switches
28 1 Protection IP 65. 2 For conduit entries M25 in place of M20 the ordering data changes from KL51V to KL11V and from KL51 to KL11. 3 Switches with cable glands. To meet the conditions of EMC (Electro Magnetic Compatibility) for connection of frequency regulated motors, maintenance switches are available with shield clips. These clips are used to continue the cable shield circuit through the enclosure. Maintenance and Safety Switches 3 pole, in Plastic Enclosure (conduit entries for metric threads) 20 A 25 A 20 A 25 A 25 A 32 A 40 A 63 A 80 A 100 A 25 A 32 A 40 A 63 A 80 A 100 A 125 A 160 A 125 A 160 A 250 A 315 A 315 A 125 A 160 A 125 A 160 A 250 A 315 A 315 A 5,5 kW / 120 A 7,5 kW / 180 A 5,5 kW / 120 A 7,5 kW / 180 A 7,5 kW / 180 A 11 kW / 220 A 15 kW / 300 A 22 kW / 350 A 30 kW / 560 A 37 kW / 650 A 7,5 kW / 180 A 11 kW / 220 A 15 kW / 300 A 22 kW / 350 A 30 kW / 560 A 37 kW / 650 A 45 kW / 750 A 55 kW / 850 A 45 kW / 750 A 55 kW / 850 A 90 kW / 1380 A 110 kW/ 1650 A 132 kW/ 2000 A 45 kW / 750 A 55 kW / 850 A 45 kW / 750 A 55 kW / 850 A 90 kW / 1380 A 110 kW/ 1650 A 132 kW/ 2000 A KG10 T103/33 KS51V KG20 T103/33 KS51V KG10 T103/75 KS51 KG20 T103/75 KS51 KG20 T103/33 KL51V KG32 T103/33 KL51V 2 KG41 T103/33 KL11V KG64 T103/33 KL11V KG80 T103/33 KL71V KG100 T103/33 KL71V KG20 T103/75 KL51 KG32 T103/75 KL51 2 KG41 T103/75 KL11 KG64 T103/75 KL11 KG80 T103/75 KL71 KG100 T103/75 KL71 KG125 T103/34 STM 1 KG160 T103/34 STM 1 KG125 T103/76 STM 1 KG160 T103/76 STM 1 KG250 T103/36 STM KG315 T103/36 STM 3 C316 T103/37 STM 3 KG125 T103/38 STM KG160 T103/38 STM KG125 T103/36 STM KG160 T103/36 STM KG250 T103/39 STM 3 KG315 T103/39 STM 3 C316 T103/39 STM 3 06743 5 06744 2 06745 9 06746 6 06747 3 06748 0 06749 7 06750 3 07454 9 07456 3 06753 4 06754 1 06755 8 06756 5 07279 8 07280 4 06759 6 06760 2 06761 9 06762 6 06763 3 06764 0 06765 7 06766 4 06767 1 06768 8 06769 5 06770 1 06771 8 06772 5 KG10 T203/33 KS51V KG20 T203/33 KS51V KG10 T203/75 KS51 KG20 T203/75 KS51 KG20 T203/33 KL51V KG32 T203/33 KL51V 2 KG41 T203/33 KL11V KG64 T203/33 KL11V KG80 T203/33 KL71V KG100 T203/33 KL71V KG20 T203/75 KL51 KG32 T203/75 KL51 2 KG41 T203/75 KL11 KG64 T203/75 KL11 KG80 T203/75 KL71 KG100 T203/75 KL71 KG125 T203/34 STM 1 KG160 T203/34 STM 1 KG125 T203/76 STM 1 KG160 T203/76 STM 1 KG250 T203/36 STM KG315 T203/36 STM 3 C316 T203/37 STM 3 KG125 T203/38 STM KG160 T203/38 STM KG125 T203/36 STM KG160 T203/36 STM KG250 T203/39 STM 3 KG315 T203/39 STM 3 C316 T203/39 STM 3 06773 2 06774 9 06775 6 06776 3 06777 0 06778 7 06779 4 06780 0 07455 6 07457 0 06783 1 06784 8 06785 5 06786 2 07281 1 07282 8 06789 3 06790 9 06791 6 06792 3 06793 0 06794 7 06795 4 06796 1 06797 8 06798 5 06799 2 06800 5 06801 2 06802 9 Oversized Wiring Space Oversized Wiring Space Version Protection Padlock IP 66/67 Device Thermal Current I the Main Switches Handle electro-gray Handle black EAN- Code 9004257 Main Switches with Emergency Function Handle red Contrasting yellow plate EAN- Code 9004257 Ratings AC-23A, AC-23B Breaking Capacity 3 x 380 V/440 V < back to table of contents >
Made with FlippingBook
RkJQdWJsaXNoZXIy MTAxNzE=