KRAUS & NAIMER Enclosures for EMC-compliant connection

Maintenance Switches for EMC-compliant Connection IEC 60204 and VDE 0113 for EMC-compliant connection of frequency-regulated motors next ►

Kraus & Naimer is a manufacturer of electrical switches, founded in 1907 and headquartered in Vienna, Austria. As a specialist for lowvoltage industrial switches, we offer both standardized and customized switching solutions. We can customize your switches by adding different extras such as padlock devices, keylock devices, auxiliary contacts und much more. As a manufacturer, supplier, and partner of choice for main switches, control and repair switches, as well as switch disconnectors, we will find the ideal solution for almost every application. Our main switches ensure reliable switching for your system. Thanks to our robust control switches, your custom system will be efficiently managed, even in the most demanding applications and harshest environmental conditions. The compact switch disconnectors provide safe disconnection under load for all low-voltage applications. Our repair and safety switches are essential components for switching off machines before maintenance. We are a trusted partner for customers from various sectors such as railways, vehicles, conveyor and lift systems as well as mechanical engineering, power generation and power distribution systems. We maintain a global production and distribution network with around 900 employees in order to offer you the best service possible. All products – both standard and custom solutions – comply with essential international regulations for safe switching and can therefore be used globally. In this catalog you will find selected products from our portfolio. Our sales team is at your disposal for any individual product inquiries. Quality since1907

3 Contact development: 3 pole with auxiliary contacts 1NC/1NO (leading off) Ith AC-3 3x400V AC-23A 3x400V Page 20 A 3,7 kW 5,5 kW 7 25 A 5,5 kW 7,5 kW 8 32 A 7,5 kW 11 kW 8 40 A 15 kW 20 kW 9 63 A 18,5 kW 22 kW 9 80 A 22 kW 30 kW 10 100 A 30 kW 37 kW 10 125 A 37 kW 45 kW 11 160 A 45 kW 55 kW 11 250 A 55 kW 90 kW 12 315 A 75 kW 110 kW 12 315 A 55 kW 132 kW 13 Contact development: 6 pole with auxiliary contacts 1NC/1NO (leading off) Ith AC-3 3x400V AC-23A 3x400V Page 25 A 5,5 kW 7,5 kW 14 32 A 7,5 kW 11 kW 14 40 A 15 kW 20 kW 15 63 A 18,5 kW 22 kW 15 80 A 22 kW 30 kW 16 100 A 30 kW 37 kW 16 125 A 37 kW 45 kW 17 160 A 45 kW 55 kW 17 200 A 37 kW 75 kW 18 315 A 55 kW 132 kW 18 Upgrade kit Page Shield wheeling kits 19 Shielding clamp (separate) 19 Table of Contents TABLE OF CONTENSTS

4 EMC-COMPLIANT CONNECTION EMC-compliant connection of frequency-controlled motors Our maintenance switches according to IEC 60204 and VDE 0113 for EMC-compliant connection of frequency-regulated motors offer many advantages: Preventing faults Thanks to the EMC-compliant add-ons, the development and propagation of electromagnetic disturbance is minimized. This is essential, when frequency converters (FC) are used, for example:  To control the speed of motors employed in production facilities  To regulate pump and fan speed in building technology  To efficiently feed energy into the grid of wind and solar power plants Easy and safe installation UOur switches are equipped with extensively connected shield clamps or with bolt clamps, which ensure continuous shielding. Our switch disconnectors are available in robust plastic enclosures (IP 66/67), ensuring an easy and safe installation. Easy Retrofitting Our shield clamps can be mounted on both sides. The scope of delivery includes shield feed-through, two shield clamps and corresponding screws. Our maintenance switches can be retrofitted with shield feed-through kits. Contact our sales team to determine if retrofitting is possible for your switch.

5 EMC-COMPLIANT CONNECTION FOR MORE SAFETY AND RELIABILITY 

6 NOTES For the rating of the switch please note that the motor may have approx. 10 % higher charging rate due to the higher loss in FU-operation e.g. a motor with 7,5 kW rating the motor current has to be determined with 16,7 A instead of 15,2 A. Each Maintenance Switch has as standard 2 auxiliary contacts, 1 NC and 1 NO. Via the NO (20 ms leading) the FU can be switched off before the main contacts of the switch open. The configuration of the Maintenance Switch between FU and motor allows the use as Disconnector up to 400 Hz and as Load Switch at frequencies from 40 Hz to 100 Hz. Maintenance Switches for EMC-compliant connection of FU-regulated drives are available either with shield clips (KS- and KL-enclosure) or with clips mounted on DIN-rails (STM-enclosure). These clips are used to continue the cable shield circuit through the enclosure. Notes < Back to the table of contents >

7 Dimensions in mm Contact development: 3 pole with auxiliary contacts 1NC/1NO (leading off) General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Lastic enclosure, protection IP 66/67, knock-outs Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With shield clips for use to continue the cable shield circuit through the enclosure Rated Data / Order Number Name Art. No. Thermal Current Ithe Utilization Category AC-23 B/A, 3x400 V Utilization Category 3x400 V Color Handle / Backing KG10.T203/D-A076.KS51V 70008610 20 A 3,7 kW 5,5 kW KG10.T103/D-A050.KS51V 70000182 20 A 3,7 kW 5,5 kW 20 A / 5,5 kWKG10 Ø 2x20 85 120 110 Ø 20 90 17 3 POLE: 20 A / 5,5 kW = .. T203 .. = .. T103 .. Wiring diagram L1 T1 L2 T2 L3 T3 PE PE 13 14 21 22 External-Ø shield 9 — 11 < Back to the table of contents >

Dimensions in mm 8 General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Lastic enclosure, protection IP 66/67, knock-outs Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With shield clips for use to continue the cable shield circuit through the enclosure Name Art. No. Ithe AC-3 3x400V AC-23A 3x400V Handle /Color KG20.T203/D-A159.KL51V 70011109 25 A 5,5 kW 7,5 kW KG20.T103/D-A126.KL51V 70011021 25 A 5,5 kW 7,5 kW KG32.T203/D-A117.KL51V 70010424 32 A 7,5 kW 11 kW KG32.T103/D-A061.KL51V 70016584 32 A 7,5 kW 11 kW 25 A / 7,5 kWKG20 32 A / 11 kWKG32 Ø 2x20 85 160 150 Ø 20 82 17 Contact development: 3 pole with auxiliary contacts 1NC/1NO (leading off) 3 POLE: 25 A / 7,5 kW – 32 A / 11 kW Wiring diagram L1 T1 L2 T2 L3 T3 PE PE 13 14 21 22 External-Ø shield 12 — 16 = .. T203 .. = .. T103 .. < Back to the table of contents >

9 Dimensions in mm Contact development: 3 pole with auxiliary contacts 1NC/1NO (leading off) General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Lastic enclosure, protection IP 66/67, knock-outs Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With shield clips for use to continue the cable shield circuit through the enclosure Name Art. No. Ithe AC-3 3x400V AC-23A 3x400V Handle /Color KA40.T203/E1.KL11V 70031247 40 A 15 kW 20 kW KA40.T103/E1.KL11V 70031241 40 A 15 kW 20 kW KA63.T203/E1.KL71V 70031244 63 A 18,5 kW 22 kW KA63.T103/E1.KL71V 70031252 63 A 18,5 kW 22 kW 40 A / 20 kWKA40 63 A / 22 kWKA63 3 POLE: 40 A / 20 kW – 63 A / 22 kW Wiring diagram L1 T1 L2 T2 L3 T3 PE PE 13 14 21 22 External-Ø shield KA40 12 — 16 KA63 23 — 29 Ø 2x40 229 250 145 124 107 17 Ø 25 KA63 = .. T203 .. = .. T103 .. Ø 2x25 100 190 178 93 17 Ø 25 KA40 < Back to the table of contents >

Dimensions in mm 10 Contact development: 3 pole with auxiliary contacts 1NC/1NO (leading off) General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Lastic enclosure, protection IP 66/67, knock-outs Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With shield clips for use to continue the cable shield circuit through the enclosure Name Art. No. Ithe AC-3 3x400V AC-23A 3x400V Handle /Color KG80.T203/D-A108.KL71V 70010474 80 A 22 kW 30 kW KG80.T103/D-A061.KL71V 70011304 80 A 22 kW 30 kW KG100.T203/D-A120.KL71V 70011306 100 A 30 kW 37 kW KG100.T103/D-A068.KL71V 70022094 100 A 30 kW 37 kW 80 A / 30 kWKG80 100 A / 37 kWKG100 Ø 2x40 229 250 145 124 107 17 Ø 25 3 POLE: 80 A / 30 kW – 100 A / 37 kW = .. T203 .. = .. T103 .. Wiring diagram L1 T1 L2 T2 L3 T3 PE PE 13 14 21 22 External-Ø shield 23 — 29 < Back to the table of contents >

Dimensions in mm 11 Contact development: 3 pole with auxiliary contacts 1NC/1NO (leading off) General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Plastic enclosure, protection IP 66/67 Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With on DIN-rails mounted clips for use to continue the cable shield circuit through the enclosure Name Art. No. Ithe AC-3 3x400V AC-23A 3x400V Handle /Color KG125.T203/D-A082.STM 70021607 125 A 37 kW 45 kW KG125.T103/D-A070.STM 70022095 125 A 37 kW 45 kW KG160.T203/D-A077.STM 70011325 160 A 45 kW 55 kW KG160.T103/D-A066.STM 70019588 160 A 45 kW 55 kW 125 A / 45 kWKG125 160 A / 55 kWKG160 180 73 280 560 534 254 KG125  2xØ63 + 1xØ20 KG160  2xØ63 + 1xØ20 3 POLE: 125 A / 45 kW – 160 A / 55 kW Wiring diagram L1 T1 L2 T2 L3 T3 PE PE 13 14 21 22 External-Ø shield 34 — 40 = .. T203 .. = .. T103 .. < Back to the table of contents >

Dimensions in mm 12 Contact development: 3 pole with auxiliary contacts 1NC/1NO (leading off) General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Plastic enclosure, protection IP 66/67 Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With on DIN-rails mounted clips for use to continue the cable shield circuit through the enclosure Name Art. No. Ithe AC-3 3x400V AC-23A 3x400V Handle /Color KG250.T203/D-A075.STM 70015149 250 A 55 kW 90 kW KG250.T103/D-A073.STM 70021751 250 A 55 kW 90 kW KG315.T203/D-A034.STM 70010413 315 A 75 kW 110 kW KG315.T103/D-A043.STM 70022022 315 A 75 kW 110 kW 250 A / 90 kWKG250 315 A / 110 kWKG315 180 73 280 560 534 254 Ø 2x63 Ø 1x20 180 73 280 560 534 254 Ø 2x20 110 110 KG250 KG315 Ø 1x28-60 3 POLE: 250 A / 90 kW – 315 A / 110 kW = .. T203 .. = .. T103 .. Wiring diagram L1 T1 L2 T2 L3 T3 PE PE 13 14 21 22 External-Ø shield KG250 34 — 40 KG315 46 — 52 < Back to the table of contents >

Dimensions in mm 13 Contact development: 3 pole with auxiliary contacts 1NC/1NO (leading off) General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Plastic enclosure, protection IP 66/67 Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With on DIN-rails mounted clips for use to continue the cable shield circuit through the enclosure Name Art. No. Ithe AC-3 3x400V AC-23A 3x400V Handle /Color C316.T203/D-A037.STM 70021610 315 A 55 kW 132 kW C316.T103/D-A025.STM 70021721 315 A 55 kW 132 kW 315 A / 132 kWC316 280 86,5 380 560 534 354 Ø 2x72 Ø 1x20 3 POLE: 315 A / 132 kW Wiring diagram L1 T1 L2 T2 L3 T3 103 104 101 102 PE PE External-Ø shield C316 46 — 52 = .. T203 .. = .. T103 .. < Back to the table of contents >

Dimensions in mm 14 Contact development: 6 pole with auxiliary contacts 1NC/1NO (leading off) General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Lastic enclosure, protection IP 66/67, knock-outs Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With shield clips for use to continue the cable shield circuit through the enclosure Name Art. No. Ithe AC-3 3x400V AC-23A 3x400V Handle /Color KG20B.T206/D-A059.KL11V 70011049 25 A 5,5 kW 7,5 kW KG20B.T106/D-A046.KL11V 70011881 25 A 5,5 kW 7,5 kW KG32B.T206/D-A054.KL11V 70011051 32 A 7,5 kW 11 kW KG32B.T106/D-A040.KL11V 70033788 32 A 7,5 kW 11 kW 25 A / 7,5 kWKG20B 32 A / 11 kWKG32B Ø 2x25 100 190 178 93 17 Ø 25 6 POLE: 25 A / 7,5 kW – 32 A / 11 kW = .. T206 .. = .. T106 .. Wiring diagram 1L2 1T2 1L1 1T1 1L3 1T3 2L2 2T2 2L1 2T1 2L3 2T3 13 14 21 22 PE PE External-Ø shield 12 — 16 < Back to the table of contents >

Dimensions in mm 15 Contact development: 6 pole with auxiliary contacts 1NC/1NO (leading off) General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Lastic enclosure, protection IP 66/67, knock-outs Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With shield clips for use to continue the cable shield circuit through the enclosure Name Art. No. Ithe AC-3 3x400V AC-23A 3x400V Handle /Color KA40B.T206/E1.KL71V 70038156 40 A 15 kW 20 kW KA40B.T106/E1.KL71V 70037283 40 A 15 kW 20 kW KA63B.T206/E1.KL71V 70039502 63 A 18,5 kW 22 kW KA63B.T106/E1.KL71V 70037281 63 A 18,5 kW 22 kW 40 A / 20 kWKA40B 63 A / 22 kWKA63B Ø 2x40 229 250 145 124 107 17 Ø 25 6 POLE: 40 A / 20 kW – 63 A / 22 kW Wiring diagram 1L2 1T2 1L1 1T1 1L3 1T3 2L2 2T2 2L1 2T1 2L3 2T3 13 14 21 22 PE PE External-Ø shield 23 — 29 = .. T206 .. = .. T106 .. < Back to the table of contents >

Dimensions in mm 16 Contact development: 6 pole with auxiliary contacts 1NC/1NO (leading off) General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Plastic enclosure, protection IP 66/67 Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With on DIN-rails mounted clips for use to continue the cable shield circuit through the enclosure Name Art. No. Ithe AC-3 3x400V AC-23A 3x400V Handle /Color KG80C.T206/D-A070.STM 70022583 80 A 22 kW 30 kW KG80C.T106/D-A055.STM 70020989 80 A 22 kW 30 kW KG100C.T206/D-A060.STM 70022584 100 A 30 kW 37 kW KG100C.T106/D-A049.STM 70022588 100 A 30 kW 37 kW 80 A / 30 kWKG80C 100 A / 37 kWKG100C 180 49,3 280 380 354 254 Ø 2x50 + 1x20 6 POLE: 80 A / 30 kW – 100 A / 37 kW = .. T206 .. = .. T106 .. Wiring diagram 1L2 1T2 1L1 1T1 1L3 1T3 2L2 2T2 2L1 2T1 2L3 2T3 13 14 21 22 PE PE External-Ø shield 28 — 34 < Back to the table of contents >

Dimensions in mm 17 Contact development: 6 pole with auxiliary contacts 1NC/1NO (leading off) General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Plastic enclosure, protection IP 66/67 Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With on DIN-rails mounted clips for use to continue the cable shield circuit through the enclosure Name Art. No. Ithe AC-3 3x400V AC-23A 3x400V Handle /Color KG125.T206/D-A020.STM 70022585 125 A 37 kW 45 kW KG125.T106/D-A031.STM 70022589 125 A 37 kW 45 kW KG160.T206/D-A040.STM 70022587 160 A 45 kW 55 kW KG160.T106/D-A024.STM 70022590 160 A 45 kW 55 kW 125 A / 45 kWKG125 160 A / 55 kWKG160 180 73 380 560 354 534 Ø 2x63 + 1x20 6 POLE: 125 A / 45 kW – 160 A / 55 kW Wiring diagram 1L2 1T2 1L1 1T1 1L3 1T3 2L2 2T2 2L1 2T1 2L3 2T3 13 14 21 22 PE PE External-Ø shield 34 — 40 = .. T206 .. = .. T106 .. < Back to the table of contents >

Dimensions in mm 18 Contact development: 6 pole with auxiliary contacts 1NC/1NO (leading off) General Data Switch Disconnectors according to EN 60947-3 and VDE 0660 part 107 Ambient temperature (enclosed): 35 ˚C during 24 hours with peaks up to 40 ˚C Equipment Plastic enclosure, protection IP 66/67 Handle in the OFF-position lockable with padlocks, special safety interlocked covers with enclosure With on DIN-rails mounted clips for use to continue the cable shield circuit through the enclosure Name Art. No. Ithe AC-3 3x400V AC-23A 3x400V Handle /Color C200-4.T206/D-A001.STM 70009765 200 A 37 kW 75 kW C200-4.T106/D-A001.STM 70023125 200 A 37 kW 75 kW C316.T206/D-A050.STM 70027327 315 A 55 kW 132 kW C316.T106/D-A033.STM 70026633 315 A 55 kW 132 kW 200 A / 75 kWC200-4 315 A / 132 kWC316 C200-4 230 73 380 560 534 354 Ø 2x63 Ø 1x20 C316 280 86,5 380 560 534 354 Ø 2x72 Ø 1x20 6 POLE: 200 A / 75 kW – 315 A / 132 kW = .. T206 .. = .. T106 .. Wiring diagram 1L1 1T1 1L2 1T2 1L3 1T3 2L1 2T1 2L2 2T2 2L3 2T3 103 104 101 102 PE PE External-Ø shield C200-4 34 — 40 C316 46 — 52 < Back to the table of contents >

Dimensions in mm 19 Shield wheeling kits Standard KS- KL-Enclosure Dimensions enclosures 85 x 120 85 x 160 100 x 190 145 x 250 External-Ø shield 9 — 11 12 — 16 12 — 16 23 — 29 Name S0E.T400.MA K0B.T400.MA K1B.T400.MA K2B.T400.MA Art. No. 2034380 2148422 2148858 2149381 Shielding clamp suitable for double side connecting. Scope of delivery: panel sheet, 2 shielding clamps, mounting screws Shield wheeling kit available for 3 pole switches up to KG100…. And 6 pole switches up to KG64. All relevant catalogue listed repair switches can be upgraded with shield wheeling kits. The switch body has to be demounted first before mounting the shield wheeling. Shielding clamp (separate) External-Ø shield 9 — 11 12 — 16 23 — 29 Name K1B.T400.KB K1B.T400.KC K1B.T400.KE Art. No. 2148854 2138231 2148856 UPGRADE KIT UPGRADE KIT < Back to the table of contents >

www.krausnaimer.com © Kraus & Naimer, 4/2025

RkJQdWJsaXNoZXIy MTAxNzE=