3 Manual transfer switch/Changeover switch Base mounting for 45 mm standard knock-out IP40 3-pole, auxiliary contacts for each position: Emergency Power and Mains Name Art. no. Type Dim. WxH mm Front size number of modules Ith AC-23A (3x400V) E-nr. KG20B.T903/S-A308.*VE 70030990 3-pole 84x75 2,5 25 A 7,5 kW 3134520 KG32B.T903/S-A308.*VE 70030834 3-pole 84x75 2,5 32 A 11 kW 3134521 KG41B.T903/S-A308.*VE 70030831 3-pole 100x92 3 40 A 15 kW 3134522 KG64B.T903/S-A308.*VE 70031010 3-pole 100x92 3 63 A 22 kW 3134523 KG80.T903/S-A308.*VE 70031018 3-pole 140x105 4 80 A 30 kW 3134524 KG100.T903/S-A308.*VE 70030651 3-pole 140x105 4 100 A 37 kW 3134525 KG105.T903/S-A308.*VE 70030642 3-pole 140x105 4 125 A 45 kW 3134519 * Does not apply to KG80-KG105, which have auxiliary contact only in emergency power mode. 4-pole, auxiliary contacts for each position: Emergency Power and Mains Name Art. no. Type Dim. WxH mm Front size number of modules Ith AC-23A (3x400V) E-nr. KG20B.T904/S-A421.*VE 70011094 4-pole 111x75 2,5 25 A 7,5 kW 3134526 KG32B.T904/S-A421.*VE 70030823 4-pole 111x75 2,5 32 A 11 kW 3134527 KG41B.T904/S-A421.*VE 70030797 4-pole 132x92 3 40 A 15 kW 3134528 KG64B.T904/S-A421.*VE 70031011 4-pole 132x92 3 63 A 22 kW 3134529 KG80.T904/S-A421.*VE 70031020 4-pole 184x105 4 80 A 30 kW 3134530 KG100.T904/S-A421.*VE 70030652 4-pole 184x105 4 100 A 37 kW 3134531 KG105.T904/S-A421.*VE 70030645 4-pole 184x105 4 125 A 45 kW 3134533 * Does not apply to KG80-KG105, which have auxiliary contact only in emergency power mode. Base mounting IP66/67 3-pole, auxiliary contacts for each position: Emergency Power and Mains Name Art. no. Type Width mm Installation depth mm Ith AC-23A (3x400V) E-nr. KG20B.T903/S-A425.*VE 70042591 3-pole 84 101-181 25 A 7,5 kW - KG32B.T903/S-A425.*VE 70042593 3-pole 84 101-181 32 A 11 kW - KG41B.T903/S-A425.*VE 70042595 3-pole 100 109-195 40 A 15 kW - KG64B.T903/S-A425.*VE 70042597 3-pole 100 109-195 63 A 22 kW - KG80.T903/S-A425.*VE 70042582 3-pole 140 122-208 80 A 30 kW - KG100.T903/S-A425.*VE 70042584 3-pole 140 122-208 100 A 37 kW - KG125.T903/S-A425.*VE 70042586 3-pole 224 153-273 125 A 45 kW - KG160.T903/S-A425.*VE 70042589 3-pole 224 153-273 160 A 55 kW - C316.T903/S-A425.*VE 70045944 3-pole 128 237-377 315 A 132 kW - 4-pole, auxiliary contacts for each position: Emergency Power and Mains Name Art. no. Type Width mm Installation depth mm Ith AC-23A (3x400V) E-nr. KG20B.T904/S-A426.*VE 70042592 4-pole 111 101-181 25 A 7,5 kW - KG32B.T904/S-A426.*VE 70042594 4-pole 111 101-181 32 A 11 kW - KG41B.T904/S-A426.*VE 70042596 4-pole 132 109-195 40 A 15 kW - KG64B.T904/S-A426.*VE 70042598 4-pole 132 109-195 63 A 22 kW - KG80.T904/S-A426.*VE 70042583 4-pole 184 122-208 80 A 30 kW - KG100.T904/S-A426.*VE 70042585 4-pole 184 122-208 100 A 37 kW - KG105.T904/S-A426.*VE 70083239 4-pole 184 122-208 125 A 45 kW - KG125.T904/S-A426.*VE 70042588 4-pole 300 153-273 125 A 45 kW - KG160.T904/S-A426.*VE 70042590 4-pole 300 153-273 160 A 55 kW - C316.T904/S-A426.*VE 70045945 4-pole 128 254-394 315 A 132 kW MANUAL TRANSFER SWITCH/CHANGEOVER SWITCH
RkJQdWJsaXNoZXIy MTAxNzE=