KRAUS & NAIMER Short Form Catalogue 2024

Issue 3 29 www.krausnaimer.com Direct Sales Line: +353 61 704700 Email: sales-ie@krausnaimer.com Switch Type Thermal Rating Insulation Voltage, Ui Rated operating Current & power Operational current, Ie Operational Power, 3 ph. Short Circuit Protection Terminal Capacity AC-15 AC-21A AC-3 AC-23A Enclosed rating Ithe 110V 220-240V 380-440V 690V 220-240V 380-440V 230-240V 380-440V Max. fuse gL/gG char. Single core/ stranded wire. Flexible wire, with sleeve. Terminal bolt for Cu bar/lug. A V A kW A mm2 mm2 mm2 Switch-diconnectors - selection data in accordance with: IEC 60947, IEC 60204, BS EN 60947, BS EN 60204 KG10 20 690 - - - 20 2.2 3.7 3 5.5 20 2.5 1.5 - KG20 25 690 - - - 25 4 5.5 5.5 7.5 35 6 4 - KG32 32 690 - - - 32 5.5 7.5 5.5 11 35 6 4 - KG41 40 690 - - - 40 7.5 11 7.5 15 50 16 10 - KG64 63 690 - - - 63 11 18.5 11 22 63 16 10 - KG80 80 690 - - - 80 15 22 18.5 30 80 50 35 - KG100 100 690 - - - 100 18.5 30 22 37 100 50 35 - KG105 125 690 - - - 125 22 37 25 45 125 50 35 - KG125 125 10001) - - - 125 22 37 30 45 125 95 70 - KG160 160 10001) - - - 160 30 45 30 55 160 95 70 - KG210 200 10001) - - - 200 37 55 37 75 200 185 120 - KG250 250 10001) - - - 250 37 55 37 90 250 185 120 - KG315 315 10001) - - - 315 45 75 55 110 315 185 120 - KH16 16 8001) - - - 16 3 5.5 4.5 7.5 25 6 4 - KH20 20 8001) - - - 20 3.5 6.5 5.5 10 32 6 4 - KH25 25 8001) - - - 25 4 7.5 7 12 35 6 4 - KH32 32 8001) - - - 32 5.5 11 9 16 35 10 6 - KH40 40 8001) - - - 40 7.5 15 11 20 50 10 6 - KH63 63 10001) - - - 63 11 22 18.5 30 80 35 25 - KH80 80 10001) - - - 80 15 30 23 40 100 35 25 - KH85 100 10001) - - - 100 3) 3) 3) 3) 100 35 25 - GB2.250/A 250 1000 - - - 250 - - 75 140 315 150 M8 GB2.315/A 315 1000 - - - 315 - - 100 160 500 240 M10 GB2.400/A 400 1000 - - - 400 - - 132 220 500 240 M10 GB2.630/A 630 1000 - - - 630 - - 200 355 800 400/2x155 M12 GB2.800/A 800 1000 - - - 800 - - 250 450 800 500/2x240 M12 GB2.1000/A 1000 1000 - - - 1000 - - - 560 1250 630/2x400 M12 GB2.1250/A 1250 1000 - - - 1250 - - - 710 1250 2x400 M12 C200-4 200 690 200 22 37 37 75 200 95 95 M8 C316 (6 pole) (in RB10, MB10, SB10 encl) 275 1000 - - - 275 37 55 75 132 315 150 150 M12 C316 (6 pole) (in RB29, MB29, SB29 encl) 315 1000 - - - 315 37 55 75 132 315 185 150 M12 C316 (3 + 4 pole) (in GP27 encl) 315 1000 - - - 315 37 55 75 132 315 150 150 M12 Switch & Control Stations - selection data in accordance with: IEC 60947, BS EN 60947. CA4 10 440 - 2.5 1.5 10 0.55 2.2 0.75 3 10 2x1.5 2x1.5 - CA25 32 690 12 12 6 32 5.5 11 7.5 15 35 2x6 2x4 - C32 50 690 16 16 7 40 7.5 15 11 22 63 2x10 2x6 - C42 63 690 - - - 63 11 18.5 15 30 80 2x16 2x10 - C80 115 690 - - - 100 15 30 30 45 125 35 25 - C125 150 690 - - - 150 22 37 37 75 200 70 50 - C200-4 200 690 - - - 200 22 37 37 75 200 95 95 M8 C315 (In MB10 encl) 275 690 - - - 275 37 55 75 132 315 150 150 M12 C315 (In MB29 encl) 315 690 - - - 315 37 55 75 132 315 185 150 M12 GB2.KN1/KN2/KN3/KN10/CA10 20 690 5 5 4 20 3 5.5 3.7 7.5 25 2x2.5 2x2.5 - GB2.KN4 20 690 - - - - 32) 5.52) - - 25 2x2.5 2x2.5 - GB2.KN5/KN6 25 690 8 8 5 25 4 7.5 5.5 11 35 2x4 2x2.5 - GB2.KN7/KN8 32 690 14 14 6 32 5.5 11 7.5 15 50 2x6 2x4 - P N/P SN 6 500 6 6 4 - - - - - 10 2.5 1.5 - Notes: 1) Only valid for no-load switching (AC-20A) above 690v. 3) KH85 is only available as 2 pole changeover switch. 2) 1 phase, 240v, rating = 1.5kW. Single phase rating @240v: AC-3 = 10kW, 62A. AC-23A = 11kW, 68A. TECHNICAL DATA

RkJQdWJsaXNoZXIy MTAxNzE=