1 Pty.Ltd. Short Form Catalogue FOR COMPLETE PRODUCT RANGE VISIT www.krausnaimer.com.au
The development of the Blue Line rotary switch, load break switch disconnector, contactor and motor starter product ranges is based on One Hundred years experience by Kraus & Naimer. In the Design and manufacture of electrical switchgear, Kraus and Naimer have pioneered the introduction of the cam operated rotary switch, and continues to be recognised as the world leader in that product field. BLUE LINE Blue Line products are protected by numerous patents throughout the industrial world. They are built to national and international standards and designed to withstand adverse temperatures and climates. Blue Line products are accepted and universally recognised for their quality and workmanship. They are supported by the world-wide sales and service organisation. The Kraus & Naimer Registered Trademark WORLDWIDE SYMBOL FOR QUALITY SWITCHGEAR 1 1 g plant was opened in Wellington to service the nd New Zealand markets, which remains a assembly centre for Australasia. neered many new developments since the first itch’ was introduced in 1949, and continues to ance on innovation, excellence and technology gh the next 100 years.
Page Rotary Cam Switches 10A - 2400A 5 - 12 - Control, Instrument, Motor Switches - Infinite number of switch programmes - CA / CG / CH Switches with fingerproof terminals - CA / CG / CH Switches with captive plus-minus terminal screws - CAD Switches having self-cleaning “H” Bridge with ‘cross wire’ contacts - CHR Switches with captive terminal screws for use with ring terminals - Special Switches designed to any contact programme UPS Maintenance Bypass Switches 13 Smart Switches (Available from wholesalers) 14 -15 Enclosed KG Main Switches 20A - 315A 16 - 18 - Padlockable maintenance and safety switches - Enclosed IP 65 protection in Plastic or Stainless Steel - 3, 4, 6 and 8 pole models available - Enclosure cable entries top, bottom, sides and rear, or blank KG Main Switches 20A - 315A 16 - 18 - Padlockable main and emergency switches - Modular frame sizes - 3, 4, 6 and 8 pole models available - Forced positive contact movement - Cam operated auxiliary contacts Application Guide AS/NZS 947 - 3 3F Lockout Isolators 19 Mains off Generator Switches Base Mount and Enclosed 20 - 21 Optional Extras and Mounting Options 22 - 23 Special Drive Options & Enclosures 24 - 25 New Products 26 - 29 Push Buttons, Pilot Lights 30 - 31 - Control and indicating devices - 22mm IP65 / IP69K - Fingerproof connections - Pot drive unit Fortress - Trapped Key Interlocking Systems 32 Operating - Handles 33 Dimensions 34 - 35 Switch Ordering Chart & Design Sheet 36 Useful Formulae & Index 37 - 38 Contents
4 Technical Data Rated Operational Current Multi cross point contacts 1V 6V 12V 24V 48V 110V 240V CA4/CG4 AC21A - - - 10 10 10 10 DC21 B - - - 10 6 0.7 0.2 H-Bridge cross wire contacts CGD4 - 1 AC21A 5 2 1.2 0.7 0.45 0.25 0.15 DC21B 3 1.2 0.7 0.4 0.25 0.13 0.08 CAD11 AC21A 5 3 2 1 0.8 0.4 0.2 DC21B 4 2.5 1.5 0.8 0.3 0.2 0.1 CAD12 AC21A - 5 5 5 4 3 2 DC21B - 4 3 2.2 1.2 0.6 0.3 Special Contact Systems CA4/CG4 (0,5 µm) CAD11/CAD12 / CGD4 - 1 C/CA KG/KH Switches: This durable switch line possesses high short circuit withstand capabilities, with positive movement during both making and breaking functions. The KG/KH range of isolators and changeover switches exhibit excellent AC-3 and AC-23 making and breaking capabilities. A high contact reliability is achieved by the use of multiple crosspoint contacts, having a fourpoint contact face to minimise contact resistance. Terminals on the CA series are accessible from both sides, and the terminals on the CG series are accessible from the rear. Both switches have finger proof terminals.These are the smallest cam switch 30mm sq. H-bridge cross wire contact system. The moving contact is made of spring type material to absorb possible contact bounce. These corrosive resistant contacts are capable of operating on systems voltages as low as 1 volt. CAD11 = Gold contacts. CAD12 = Silver contacts. Both switches have screw driver guides, finger proof terminals and captive plus-minus terminal screws capable of accepting two variant cable sizes. Switches C/CA have finger proof terminals and captive plus-minus terminal screws. Each stage contains two rigid, double-break silver alloy contacts. The terminals are accessible from both sides. Ranging from 20 ~ 315 amperes these switches will accept a wide range of “optional extras”. This ‘Short Form’ catalogue illustrates only a small selection of the KRAUS & NAIMER switches. Other switches available are:- A11, A14, AD11, AD12, CH10 ~ CHR16B, DH, DHR, DK, DKR, L350 ~ L1251,X200 ~ X630. Additional information available on request. G20 (S) DC SWITCHING WITH KNIFE CONTACTS Refer Page 29
Rotary Cam Switches Rated Values . Escutcheon Plate Dimensions Note: for drilling details refer to pages 34 & 35 S1 S2 S3 S0 S00 For Safety and Maintenance Switches Refer Page 16-19 5 According to IEC 60947-3/VDE 0660, part 107 Nominal Thermal Motor Rating Voltage Current 3 x 380 V - 440 V Ui Iu/Ith AC-23A AC-3 V A kW kW 440 10 3 2.2 440 10 3 2.2 690 20 7.5 5.5 690 20 7.5 5.5 690 25 11 7.5 690 32 15 11 690 20 7.5 5.5 690 25 11 7.5 690 20 7.5 5.5 690 25 11 7.5 690 32 15 11 690 40 18.5 15 690 50 22 18.5 690 63 30 18.5 690 32 15 11 690 50 22 15 690 63 30 18.5 690 20 7.5 5.5 690 25 11 7.5 690 63 30 18.5 690 115 45 30 690 150 75 37 690 200 75 37 690 315 132 55 1000 315 132 55 690 500 132 55 690 800* 132 55 690 1100* 132 55 690 1450* 132 55 690 1900* 132 55 690 2400* 132 55 According to IEC 60947-3/VDE 0660, part 107 TYPE CA4 CG4 CG 8 CA10 CA20 CA25 CH10 CH16 CA10B CA20B CA25B CA40 CA50 CA63 C26 C32 C42 CHR10B CHR20B C43 C80 C125 C200-4 C315 C316 L400 L600 L800 L1200 L1600 L2000 Cable mm2 2 x 1.5 2 x 1.5 2 x 2.5 2 x 2.5 2 X 4 2 x 6 2 x 4 2 x 4 2 x 2.5 2 x 4 2 x 6 1 x 16 1 x 16 1 x 16 2 x 6 2 x 10 2 x 16 Ring Ring 2 x 16 35 70 M8 M12 M12 M12 M16 M16 M16 2 X M16 2 X M16 For further technical details, refer to Catalogue 100 and 120. Gold contacts and quick connects see Catalogue 100 P4. * MAX AMBIENT TEMP, 35oC
6 CG 4 A202-620 E CA 10 A202-620 E CH 10 A202-620 E CA20 A202-620 E CA25 A202-620 E CA40/C26 A202-620 E CA50/C32 A202-620 E CA63/C42 A202-620 E C80 A202-620 E C125 A202-620 E C200-4 A202-620 E C315 A202-620 E CG 4 A200-620 E CA 10 A200-620 E CH 10 A200-620 E CA20 A200-620 E CA25 A200-620 E CA40/C26 A200-620 E CA50/C32 A200-620 E CA63/C42 A200-620 E C80 A200-620 E C125 A200-620 E C200-4 A200-620 E C315 A200-620 E 1 Pole CG 4 A290-621 E CA 10 A290-621 E CH 10 A290-621 E CA20 A290-621 E CA25 A290-621 E CA40/C26 A290-621 E CA50/C32 A290-621 E CA63/C42 A290-621 E C80 A290-621 E C125 A290-621 E C200-4 A290-621 E C315 A290-621 E CG 4 A292-621 E CA10 A292-621 E CH10 A292-621 E CA20 A292-621 E CA25 A292-621 E CA40/C26 A292-621 E CA50/C32 A292-621 E CA63/C42 A292-621 E C80 A292-621 E C125 A292-621 E C200-4 A292-621 E C315 A292-621 E CG 4 A326-621 E CA10 A326-621 E CH10 A326-621 E CA20 A326-621 E CA25 A326-621 E CA40/C26 A326-621 E CA50/C32 A326-621 E CA63/C42 A326-621 E C80 A326-621 E C125 A326-621 E C200-4 A326-621 E Rotary Cam Switches - Panel Mounting CG4 A290 FS2 CA10 A291 E Code No. Code No. Front Plate Function Selection Data IEC 60947-3, EN 60947, VDE 0660 Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW C 42 CA 63 63 30 CG 4 CA 4 10 3 CG 8 CH 10 CA 10 20 7.5 C 80 115 45 CA20 CA20B 25 11 C125 150 75 C26 CA25 32 15 CA 40 40 18.5 C32 CA 50 50 22 OFF / ON Switches 90° Switching Waterproof switches to IP 65 available in E24 Mounting - no additional price 1 - 8 Pole OFF / ON Switches 60° Switching 1 - 4 Pole 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 No. of Stages 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 4 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 No. of Stages 2 Pole CG 4 A291-621 E CA 10 A291-621 E CH 10 A291-621 E CA20 A291-621 E CA25 A291-621 E CA40/C26 A291-621 E CA50/C32 A291-621 E CA63/C42 A291-621 E C80 A291-621 E C125 A291-621 E C200-4 A291-621 E C315 A291-621 E CG 4 A324-621 E CA10 A324-621 E CH10 A324-621 E CA20 A324-621 E CA25 A324-621 E CA40/C26 A324-621 E CA50/C32 A324-621 E CA63/C42 A324-621 E C80 A324-621 E C125 A324-621 E C200-4 A324-621 E C315 A324-621 E CG 4 A344-620 E CA10 A344-620 E CH10 A344-620 E CA20 A344-620 E CA25 A344-620 E CA40/C26 A344-621 E CA50/C32 A344-621 E CA63/C42 A344-621 E C80 A344-620 E C125 A344-620 E C200-4 A344-620 E C315 A344-620 E 1 Pole 3 Pole 6 Pole 8 Pole - 60° 3 Pole 4 Pole C315 315 132 L400 500 132 C200-4 200 75
7 Rotary Cam Switches - Panel Mounting Function Front Code No. No of Code No. No. of Plate Stages Stages Function Code No. Function Code No. Gang Switches - Sequence Switching - 620 - 623 CG4 A210 FS2 CA10 A211 E Special Application Ship To Shore, UPS Bypass(2), Series Parallel, Special Meter, For further information, contact your nearest KRAUS & NAIMER stockist. (1) If Preclosing 4th Pole Required Change A213 To A663 (2) UPS Bypass Switches, see p13 Selection Data IEC 60947-3, EN 60947, VDE 0660 Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW C 42 CA 63 63 30 CG 4 CA 4 10 3 CG 8 CH 10 CA 10 20 7.5 C 80 115 45 CA20 CA20B 25 11 C125 150 75 C26 CA25 32 15 CA 40 40 18.5 C32 CA 50 50 22 C315 315 132 L400 500 132 C200-4 200 75 OFF / A / A + B 60° Switching OFF / A / A + B 60° Switching OFF / A / A + B 60° Switching OFF / A / A + B/ A+B+C 30° Switching 1 Pole 2 Pole 3 Pole Without Bridges CA10 A310 - 620 E CA10 A312 - 620 E CA10 WAA314 - 620 E CA10 A311 - 620 E 2 Pole CG4 A211 - 620 E 2 CA10 A211 - 620 E 2 CH10 A211 - 620 E 2 CA20 A211 - 620 E 2 CA25 A211 - 620 E 2 CA40/C26 A211 - 620 E 2 CA50/C32 A211 - 620 E 2 CA63/C42 A211 - 620 E 2 C80 A211 - 620 E 2 C125 A211 - 620 E 2 C200-4 A211 - 620 E 2 C315 A211 - 620 E 2 4 Pole(1) CG4 A213 - 620 E 4 CA10 A213 - 620 E 4 CH10 A213 - 620 E 4 CA20 A213 - 620 E 4 CA25 A213 - 620 E 4 CA40/C26 A213 - 620 E 4 CA50/C32 A213 - 620 E 4 CA63/C42 A213 - 620 E 4 C80 A213 - 620 E 4 C125 A213 - 620 E 4 C200-4 A213 - 620 E 4 C315 A213 - 620 E 4 8 Pole CA10 WAA364 - 620 E 8 1 Pole CG4 A210 - 620 E 1 CA10 A210 - 620 E 1 CH10 A210 - 620 E 1 CA20 A210 - 620 E 1 CA25 A210 - 620 E 1 CA40/C26 A210 - 620 E 1 CA50/C32 A210 - 620 E 1 CA63/C42 A210 - 620 E 1 C80 A210 - 620 E 1 C125 A210 - 620 E 1 C200-4 A210 - 620 E 1 C315 A210 - 620 E 1 3 Pole CG4 A212 - 620 E 3 CA10 A212 - 620 E 3 CH10 A212 - 620 E 3 CA20 A212 - 620 E 3 CA25 A212 - 620 E 3 CA40/C26 A212 - 620 E 3 CA50/C32 A212 - 620 E 3 CA63/C42 A212 - 620 E 3 C80 A212 - 620 E 3 C125 A212 - 620 E 3 C200-4 A212 - 620 E 3 C315 A212 - 620 E 3 6 Pole CA10 A362 - 620 E 6
8 Rotary Cam Switches - Panel Mounting KG Switch CA10 A220 E See P17~ P20 Changeover Switches without Centre “OFF” 60° Switching 8 Pole Function Front Code No. No of Code No. No. of Plate Stages Stages Front Code No. No of Code No. No of Plate Stages Stages 1 Pole CG4 A220 - 600 E 1 CA10 A220 - 600 E 1 CH10 A220 - 600 E 1 CA20 A220 - 600 E 1 CA25 A220 - 600 E 1 CA40/C26 A220 - 600 E 1 CA50/C32 A220 - 600 E 1 CA63/C42 A220 - 600 E 1 C80 A220 - 600 E 1 C125 A220 - 600 E 1 C200-4 A220 - 600 E 1 C315 A220 - 600 E 1 3 Pole CG4 A222 - 600 E 3 CA10 A222 - 600 E 3 CH10 A222 - 600 E 3 CA20 A222 - 600 E 3 CA25 A222 - 600 E 3 CA40/C26 A222 - 600 E 3 CA50/C32 A222 - 600 E 3 CA63/C42 A222 - 600 E 3 C80 A222 - 600 E 3 C125 A222 - 600 E 3 C200-4 A222 - 600 E 3 C315 A222 - 600 E 3 6 Pole CA10 A370-600 E 6 0-7 Binary CAD11 A540 - 600 E 2 CAD12 A540 - 600 E 2 0-7 Complement CAD11 A541 - 600 E 2 CAD12 A541 - 600 E 2 0-7 + Complement CAD11 WAA542 - 600 E 3 CAD12 WAA542 - 600 E 3 2 Pole CG4 A221 - 600 E 2 CA10 A221 - 600 E 2 CH10 A221 - 600 E 2 CA20 A221 - 600 E 2 CA25 A221 - 600 E 2 CA40/C26 A221 - 600 E 2 CA50/C32 A221 - 600 E 2 CA63/C42 A221 - 600 E 2 C80 A221 - 600 E 2 C125 A221 - 600 E 2 C200-4 A221 - 600 E 2 C315 A221 - 600 E 2 4 Pole (1) CG4 A223 - 600 E 4 CA10 A223 - 600 E 4 CH10 A223 - 600 E 4 CA20 A223 - 600 E 4 CA25 A223 - 600 E 4 CA40/C26 A223 - 600 E 4 CA50/C32 A223 - 600 E 4 CA/63C42 A223 - 600 E 4 C80 A223 - 600 E 4 C125 A223 - 600 E 4 C200-4 A223 - 600 E 4 C315 A223 - 600 E 4 8 Pole CA10 A372-600 E 8 0-11 Binary CAD11 A543 - 600 E 2 CAD12 A543 - 600 E 2 0-9 Binary CAD11 A550 - 600 E 2 CAD12 A550 - 600 E 2 0-9 Complement CAD11 A551 - 600 E 2 CAD12 A551 - 600 E 2 CG4-1 = Gold Plated Contact POA CAD11 = Gold Wiping H-bridge Contacts CAD12 = Silver Wiping H-bridge Contacts Binary Coded Decimal Switches - from 1 Volt. For PLC and Electronic Applications. Additional positions and combinations available on request. A542 A541 A540 (1) If Preclosing 4th Pole Required Change A223 To A673 Selection Data IEC 60947-3, EN 60947, VDE 0660 Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW C 42 CA 63 63 30 CG 4 CA 4 10 3 CG 8 CH 10 CA 10 20 7.5 C 80 115 45 CA20 CA20B 25 11 C125 150 75 C26 CA25 32 15 CA 40 40 18.5 C32 CA 50 50 22 C315 315 132 L400 500 132 C200-4 200 75
9 Rotary Cam Switches - Panel Mounting CG4 A230 FS2 CA10 A251 E Code No. Code No. Front Plate Function 1 Pole CG 4 A230 - 600 E CA10 A230 - 600 E CH10 A230 - 600 E CA20 A230 - 600 E 3 Pole CG 4 A270 - 600 E CA10 A270 - 600 E CH10 A270 - 600 E CA20 A270 - 600 E 5 Pole CA10 WAA484 - 600 E 2 Pole CG 4 A250 - 600 E CA10 A250 - 600 E CH10 A250 - 600 E CA20 A250 - 600 E 4 Pole CG 4 A476 - 600 E CA10 A476 - 600 E CH10 A476 - 600 E CA20 A476 - 600 E 6 Pole CA10 WAA489 - 600 E 1 Pole CG 4 A232 - 600 E CA10 A232 - 600 E CH10 A232 - 600 E CA20 A232 - 600 E 3 Pole CG 4 WAA272 - 600 E CA10 WAA272 - 600 E CH10 WAA272 - 600 E CA20 WAA272 - 600 E 1 Pole CG 4 A233 - 600 E CA10 A233 - 600 E CH10 A233 - 600 E CA20 A233 - 600 E 1 Pole CG 4 A231 - 600 E CA10 A231 - 600 E CH10 A231 - 600 E CA20 A231 - 600 E 3 Pole CG 4 A271 - 600 E CA10 A271 - 600 E CH10 A271 - 600 E CA20 A271 - 600 E 4 Step Switches without “OFF” 60° Switching 1 - 4 Pole 3 Step Switches without “OFF” 60° Switching 1 pole 1 - 3 Pole Drawing for 4 - 6 Pole on Request 5 Step Switches without “OFF” 60° Switching 1 - 3 Pole 6 Step Switches without “OFF” 60° Switching 1 - 2 pole 2 Pole CG 4 A251 - 600 E CA10 A251 - 600 E CH10 A251 - 600 E CA20 A251 - 600 E 4 Pole CG 4 A477 - 600 E CA10 A477 - 600 E CH10 A477 - 600 E CA20 A477 - 600 E 2 Pole CG 4 A252 - 600 E CA10 A252 - 600 E CH10 A252 - 600 E CA20 A252 - 600 E 2 Pole CG 4 WAA253 - 600 E CA10 WAA253 - 600 E CH10 WAA253 - 600 E CA20 WAA253 - 600 E No. of Stages No. of Stages 2 2 2 2 5 5 5 5 8 3 3 3 3 6 6 6 6 9 2 2 2 2 6 6 6 6 4 4 4 4 8 8 8 8 3 3 3 3 8 8 8 8 5 5 5 5 3 3 3 3 6 6 6 6 Refer to catalogue or enquire for details on additional ‘standard’ switches. Selection Data IEC 60947-3, EN 60947, VDE 0660 Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW C 42 CA 63 63 30 CG 4 CA 4 10 3 CG 8 CH 10 CA 10 20 7.5 C 80 115 45 CA20 CA20B 25 11 C125 150 75 C26 CA25 32 15 CA 40 40 18.5 C32 CA 50 50 22 C315 315 132 L400 500 132 C200-4 200 75
10 Rotary Cam Switches - Panel Mounting CG4 A240 FS2 CA10 A280 E Code No. Code No. Front Plate Function 3 Pole CA10 WAA273-600 E CH10 WAA273-600 E CA20 WAA273-600 E 1 Pole CG 4 A240 - 620 E CA10 A240 - 620 E CH10 A240 - 620 E CA20 A240 - 620 E 2 Step Switches with “OFF” 60° Switching 1 - 4 Pole 1 Pole CG 4 A241 - 620 E CA10 A241 - 620 E CH10 A241 - 620 E CA20 A241 - 620 E 3 Pole CG 4 A281 - 620 E CA10 A281 - 620 E CH10 A281 - 620 E CA20 A281 - 620 E 1 Pole CG 4 A242 - 620 E CA10 A242 - 620 E CH10 A242 - 620 E CA20 A242 - 620 E 3 Pole CG 4 WAA282 - 620 E CA10 WAA282 - 620 E CH10 WAA282 - 620 E CA20 WAA282 - 620 E 3 Step Switches with “OFF” 45° Switching 1 - 3 Pole 4 Pole Drawing on Request 4 Step Switches with “OFF” 30° Switching 1 - 4 Pole 2 Pole CG 4 A260 - 620 E CA10 A260 - 620 E CH10 A260 - 620 E CA20 A260 - 620 E 4 Pole CG 4 WAA480 - 620 E CA10 WAA480 - 620 E CH10 WAA480 - 620 E CA20 WAA480 - 620 E 2 Pole CG 4 A261 - 620 E CA10 A261 - 620 E CH10 A261 - 620 E CA20 A261 - 620 E 4 Pole CG 4 WAA481 - 620 E CA10 WAA481 - 620 E CH10 WAA481 - 620 E CA20 WAA481 - 620 E 2 Pole CG 4 WAA262 - 620 E CA10 WAA262 - 620 E CH10 WAA262 - 620 E CA20 WAA262 - 620 E 4 Pole CG 4 WAA482 - 620 E CA10 WAA482 - 620 E CH10 WAA482 - 620 E CA20 WAA482 - 620 E No. of Stages 9 9 9 No. of Stages 1 1 1 1 3 3 3 3 2 2 2 2 4 4 4 4 2 2 2 2 5 5 5 5 3 3 3 3 6 6 6 6 2 2 2 2 6 6 6 6 4 4 4 4 8 8 8 8 6 Step Switches cont. 3 Pole 3 Pole CG 4 A280 - 620 E CA10 A280 - 620 E CH10 A280 - 620 E CA20 A280 - 620 E This catalogue lists some of the many common ‘Standard Switches’ available. For additional selection refer to catalogue 100 or enquire. 4 Pole drawing on request Selection Data IEC 60947-3, EN 60947, VDE 0660 Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW C 42 CA 63 63 30 CG 4 CA 4 10 3 CG 8 CH 10 CA 10 20 7.5 C 80 115 45 CA20 CA20B 25 11 C125 150 75 C26 CA25 32 15 CA 40 40 18.5 C32 CA 50 50 22 C315 315 132 L400 500 132 C200-4 200 75 Refer to catalogue or enquire for details on additional ‘standard’ switches.
11 Rotary Cam Switches - Panel Mounting CG4 A244 FS2 CA10 A263 E-V Code No. Code No. Front Plate Function 1 Pole CG 4 A243 - 620 E CA10 A243 - 620 E CH10 A243 - 620 E CA20 A243 - 620 E 3 Pole CG 4 WAA283 - 620 E CA10 WAA283 - 620 E CH10 WAA283 - 620 E CA20 WAA283 - 620 E 1 Pole CG 4 A244 - 620 E CA10 A244 - 620 E CH10 A244 - 620 E CA20 A244 - 620 E 3 Pole CA10 WAA284 - 620 E CH10 WAA284 - 620 E CA20 WAA284 - 620 E 5 Step Switches with “OFF” 30° Switching 1 - 3 Pole 6 Step Switches with “OFF” 30° Switching 1 - 3 Pole 2 Pole CG 4 WAA263 - 600 E CA10 WAA263 - 600 E CH10 WAA263 - 600 E CA20 WAA263 - 600 E 2 Pole CG 4 WAA264 - 620 E CA10 WAA264 - 620 E CH10 WAA264 - 620 E CA20 WAA264 - 620 E Double Throw Spring Return to “OFF” 30° Switching 1 - 3 Pole 1 Pole CA10 A214 - 620 E CH10 A214 - 620 E 3 Pole CA10 A216 - 620 E CH10 A216 - 620 E 1 Pole CA10 A176 - 600 E CH10 A176 - 600 E Stop Start Switch 30° Switching 1 Pole CA10 A178 - 620 E Stop Start Switch Spring return to “RUN” 2 Pole CA10 A215 - 620 E CH10 A215 - 620 E No. of Stages 3 3 3 3 8 8 8 8 No. of Stages 5 5 5 5 3 3 3 3 9 9 9 6 6 6 6 1 1 3 3 2 2 1 1 1 2 Pole CA10 WAA183 - 600 E 2 CH10 WAA183 - 600 E 2 Selection Data IEC 60947-3, EN 60947, VDE 0660 Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW C 42 CA 63 63 30 CG 4 CA 4 10 3 CG 8 CH 10 CA 10 20 7.5 C 80 115 45 CA20 CA20B 25 11 C125 150 75 C26 CA25 32 15 CA 40 40 18.5 C32 CA 50 50 22 C315 315 132 L400 500 132 C200-4 200 75 Refer to catalogue or enquire for details on additional ‘standard’ switches. Refer to catalogue or enquire for details on additional ‘standard’ switches. Refer to catalogue or enquire for details on additional ‘standard’ switches. Refer to catalogue or enquire for details on additional ‘standard’ switches.
12 Y Rotary Cam Switches - Panel Mounting CA10 AU9Y96-600FT2 Code No. Code No. Front Plate Function Motor Reversing 3 Phase 60° Switching Off-Star-Delta Meter/Motor Switches 3 Phase - 3 Wire 3 Ph - Ph / 3 Ph - N CA10 A004 - 625 E CH10 A004 - 625 E Meter Switches A038 1 Pole - 3 Current Transformers CA10 A038 - 622 E CA40/C26 A038 - 622 E 2 Pole - 3 Current Transformers (Can be used for direct reading) 1 Pole - 4 Current Transformers CA10 WAA036 - 620 E CH10 WAA036 - 620 E No. of Stages 3 3 4 4 2 2 3 3 5 5 3 3 4 4 No. of Stages Single or Three phase 90° Enclosed IP65 3 3 Split Phase CA10 WAA622 - 600 E CA20B WAA622 - 600 E 3 3 ∆ Tap wound Motor (2 Speed) 4 4 CA10 A410 - 620 E CA40/C26 A410 - 620 E CA10 A007/AU2122 E CH10 A007/AU2122 E CA10 A058/AUN0180 E CH10 A058/AUN0180 E Single Phase Rev. 3 Phase Rev. M3 M1 M2 1 3 5 7 2 4 6 10 L3 L1 L2 1 3 5 7 2 4 6 10 Run Start 3 3 CA10 A228 - 600 E CA40/C26 WAA228 - 600 E CA10 A441 - 620 E CA20 A441 - 620 E Motor Reversing 3 Phase Spring Return A007 A004 A048 A036 A038 CA10C2Y096*PFAUS0001 CA10 AU9Y96600FT20002 Selection Data IEC 60947-3, EN 60947, VDE 0660 Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW Rated Thermal Current IU = Ith A Rated Category 3 x 380 V/440 V AC-23A kW C 42 CA 63 63 30 CG 4 CA 4 10 3 CG 8 CH 10 CA 10 20 7.5 C 80 115 45 CA20 CA20B 25 11 C125 150 75 C26 CA25 32 15 CA 40 40 18.5 C32 CA 50 50 22 C315 315 132 L400 500 132 C200-4 200 75 CA10 A401 - 620 E CA40/C26 A401 - 620 E
13 UPS – Maintenance Bypass Switches Maintenance Bypass Switches Kraus & Naimer Maintenance Bypass Switches are an accepted industrial standard wherever emergency power equipment is installed and maintained. The Maintenance Bypass Switch can be utilized as a simple method of isolating a UPS without interrupting the power source. This allows servicing of the UPS with complete safety to maintenance personnel. A wide range of models has been established, while a broad selection of designer specified options is available on request. Options Include Maintenance Bypass Switches are available as - Switch only, Enclosed or Enclosed wired to terminals. 1. Key interlock (V760) with auxiliaries for signal confirmation on locking/unlocking or to shut down the inverter of a UPS prior to switching to the bypass position. 2. Push button interlock with auxiliaries (V400). Switching only possible if push button is depressed, simultaneously closing or opening auxiliaries for signal confirmation to the UPS. 3. A solenoid interlock device (V140) that prevents the operation of the switch except under predetermined electrical conditions. 4. Automatic changeover switches also available. Current rating to AC22A – 240v amps max. cable size KVA ratings to AC22A – 240v KVA CA10B 16 2.5mm CA10B 3.68 C26 32 6mm C26 7.3 C42 63 16mm C42 14 Current rating to AC22A – 415V amps max. cable size KVA ratings to AC22A – 415v KVA CA10B 16 2.5mm CA10B 11.5 C26 32 6mm C26 23 C42 63 16mm C42 45 C80 100 35mm C80 72 C125 150 70mm C125 107 C200-4 200 M8 95mm C200-4 143 C315 315 M12 185mm C315 225 V760 V400 V140 Enclosed & Wired to Terminals
14 These devices only fit switches with the same colour identification label Black Label - Handles and Optional Extras fit all Switches Switch Body Match the label colours to ensure the switch body and handle, key or padlock device are compatible. Key KN14 Padlock Red/Yellow KN15 Padlock Red/Black KN25 Key KN21 Key Removable Both Positions Handle KN23 Handle KN22 IP 65 Enclosed KN24 DIN Rail Mnt KN30 Key KN18 Key Removable Off Only KN11 1 Pole 20 A KN12 2 Pole 20 A KN13 3 Pole 20 A KN27 3 Pole 32 A Reversing Switch Single or 3 Phase Man - Off - Auto Man - Auto KN26 KN16 1 Pole KN17 3 Pole KN19 1 Pole KN20 3 Pole Off - On Smart Switch
15 Code Description 20 1 Pole KN11 20 2 Pole KN12 20 3 Pole KN13 OFF - ON switch body only MAN - OFF - AUTO switch body only 20 1 Pole KN16 20 3 Pole KN17 MAN - AUTO switch body only 20 1 Pole KN19 20 3 Pole KN20 20 1 phase or 3 phase KN26 Red / Yellow KN15 For OFF ON KN14 For MAN OFF AUTO KN18 For MAN AUTO KN21 Round bezel KN22 Standard square frame KN23 Drilled enclosure KN24 FOR - OFF - REV switch body only FOR - OFF - REV switch enclosed - IP 66 Padlocking Handles Key Operators Select by Switch Function Handle Operators (Plates are included with switch body) Mounting Accessories Amps Smart Switchess 22mm IP66 Protection
16 KG Main Switches Nominal Ratings IEC 60947-3 SWITCHES - DISCONNECTORS - SWITCH DISCONNECTORS IEC 60947 is a safety and performance standard for low voltage switchgear (up to 1000V) which has universally replaced IEC 408 and combined specific requirements of many individual national standards. IEC 60947 is a uniform standard for most countries around the world and establishes a truly global marketplace. IEC 60947-3 is a section of the standard specific to switches. Importantly, it recognises that devices for the switching function and isolating function require very different performance criteria. Switching requires high performance of current carrying parts to make and break loads under normal and overload conditions, ie., motor reversing applications. Isolation requires high insulation, sufficient spacing of current carrying parts and mechanical integrity that the handle corresponds to actual contact position for the safety of maintenance personnel. Practicality of real life applications calls for three definitions within IEC 60947-3; Switches, Disconnectors and Switch Disconnectors. A switch does not have to satisfy the isolation and mechanical strength tests, and a disconnector likewise the load tests. A Switch Disconnector must satisfy all tests and is suitable for safety switch applications. A switch disconnector must have a direct drive late make early break auxiliary contact in series with a load breaking device to be suitable as a safety switch. Kraus & Naimer have developed complete products which satisfy all IEC 60947 criteria, some of which are listed overleaf. For further information, please contact our offices. Frame Size S0/S1 S0/S1 S0/S1 S0/S1 S0/S1 S1 S1 S1 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 Type KG10A/KG10B KG20A/KG20B KG32A/KG32B KG41/KG41B KG64/KG64B KG80 KG100 KG105 KG125 (Tunnel) KG126 (Lugs) KG127 (Both) KG160 (Tunnel) KG161 (Lugs) KG162 (Both) KG210 (Tunnel) KG211 (Lugs) KG212 (Both) KG250 (Tunnel) KG251 (Lugs) KG252 (Both) KG315 (Tunnel) KG316 (Lugs) KG317 (Both) FOR HIGHER CURRENT RATINGS Please contact your nearest KRAUS & NAIMER stockist. S2 = 88mm x 88mm S1 = 64mm x 64mm S0 = 48mm x 48mm Cable Size mm2 2.5 6 6 16 16 50 50 50 95 M10 Both 95 M10 Both 185 M12 Both 185 M12 Both 185 M12 Both IEC 60947-3/VDE 0660, part 107 Rated Values Thermal Operational Utilization Category Current Current AC-23A AC-3 Iu/Ith AC-21A 3 x 380 V - 440 V A A kW kW 20 20 5.5 3.7 25 25 7.5 5.5 32 32 11 7.5 40 40 15 11 63 63 22 18.5 80 80 30 22 100 100 37 30 125 125 45 37 125 125 45 37 160 160 55 45 200 200 75 55 250 250 90 55 315 315 110 75
17 Code No. KG Main Switches - Padlockable Panel Mount, Enclosed Plastic or Stainless Steel Code No. Selection Data IEC 60947, EN 60947, VDE 0660 IEC 204, EN 60204, VDE 0113 Nominal Voltage Ui V Thermal Current IU / Ith A Enclosed Thermal Current Ithe A Operational Current AC21A Ie A Utilisation Category 3 x 380V / 440V AC-23A/B kW KG125 KG126 KG127 1000 (2) 125 125 125 45 KG100 690 100 100 100 37 KG80 690 80 80 80 30 KG64 KG64B 690 63 63 63 22 KG32 KG32B 690 32 32 32 11 KG20 KG20B 690 25 25 25 7,5 KG10 KG10B 690 20 20 20 5,5 KG160 KG161 KG162 1000 (2) 160 160 160 55 KG250 KG251 KG252 1000(2) 250 250 250 90 KG210 KG211 KG212 1000(2) 200 200 200 75 Switch Type KG41 KG41B 690 40 40 40 15 Product Panel Mount IP65 Size 0 = 48 x 48 Red / Yellow Padlock Handle - V840G/D C/W Off . On Escutcheon Panel Mount - Lockable 3 Pole KG10B K300*AU2100 E KG20B K300*AU2100 E KG32B K300*AU2100 E KG41B K300*AU2100 E KG64B K300*AU2100 E KG80 K300*AU2100 E KG100 K300*AU2100 E KG105 K300*AU2100 E KG126 K300*AU2100 E KG161 K300*AU2100 E KG211 K300*AU2100 E KG251 K300*AU2100 E KG316 K300*AU2100 E Panel Mount - Lockable 3 Pole . KG10B K302*AU2100 E KG20B K302*AU2100 E KG32B K302*AU2100 E KG41B K302*AU2100 E KG64B K302*AU2100 E KG80 K302*AU2100 E KG100 K302*AU2100 E KG105 K302*AU2100 E KG126 K302*AU2100 E KG161 K302*AU2100 E KG211 K302*AU2100 E KG251 K302*AU2100 E KG316 K302*AU2100 E Panel Mount - Lockable 4 Pole KG10B K400*AU2100 E KG20B K400*AU2100 E KG32B K400*AU2100 E KG41B K400*AU2100 E KG64B K400*AU2100 E KG80 K400*AU2100 E KG100 K400*AU2100 E KG105 K400*AU2100 E KG126 K400*AU2100 E KG161 K400*AU2100 E KG211 K400*AU2100 E KG251 K400*AU2100 E KG316 K400*AU2100 E Enclosed - Plastic - Lockable 3 Pole KG20A T203/AU1902 PFE1 KG32A T203/AU1902 PFE1 KG41 K302-PFE1 AUS0001 KG41 K302*AU0162*KL12 KG64 K302-PFE1 AUS0001 KG64 K302*AU0162*KL12 KG80 K302*AU0163*KL12 KG100 K302*AU0163*KL12 KG126 K302*AU0760*6FE KG161 K302*AU0760*6FE KG211 K302*AU0171*6FE KG251 K302*AU0171*6FE KG316 K302*AU0171*6FE Enclosed - Plastic - Lockable 3 Pole KG20B K302*AU0160*KL12 KG32B K302*AU0160*KL12 KG41B K302*AU0152*KL12 KG64B K302*AU0152*KL12 KG80 K302*AU0153*6FE KG100 K302*AU0153*6FE KG126 K302*AU0761*6FE KG161 K302*AU0761*6FE KG211 K302*AU0172*6AEmetal KG251 K302*AU0172*6AEmetal KG316 K302*AU0172*6AEmetal Enclosed - Plastic - Lockable 3 Pole C/O with centre OFF KG20B K900*AU0157*KL12 KG32B K900*AU0157*KL12 KG41B K900*AU0158*KL12 KG64B K900*AU0158*KL12 KG80 K900*AU0159*6FE KG100 K900*AU0159*6FE Plastic Enclosure IP65 Red / Yellow Padlock Handle - V845 Stainless Steel Enclosure IP65 Stainless Steel Enclosures. . . Marine Grade 316 IP65 N/O contact late make early break. Finish:- Bead Blast or Food Industry.(FI) Available on request:- Integrated Rain Hood. Hinged Door. Mounting Flanges Stainless Steel Padlock Device Variations on request:- Stop/Start Pushbuttons. Control & Changeover Switches. Selection of auxiliary contacts. KG41B K302*AU1150*6SH1 KG64B K302*AU1150*6SH1 KG80 K302*AU1148*6SH1 KG100 K302*AU1148*6SH1 KG125 K302*AU1145*6SH2 KG161 K302*AU1145*6SH2 KG211 K302*AU1151*6SH3 KG251 K302*AU1151*6SH3 KG316 K302*AU1151*6SH3 KG20A K302*AUN0478*6SS0 KG32A K302*AUN0478*6SS0 KG41B K302*AUN0479*6SS1 KG64B K302*AUN0479*6SS1 KG80 K302*AUN0479*6SS1 KG100 K302*AUN0479*6SS1 KG125 K302*AUN0480*6SS2 KG161 K302*AUN0480*6SS2 Enclosed - Lockable Stainless Steel 3 pole KG315 KG316 KG317 1000(2) 315 315 315 110 Enclosed - Lockable Stainless Steel 3 Pole (1) 4 Pole changeover enclosed. Refer page 20. For Panel and Base mount 4 Pole changeover Refer to page 20. (2) Suitable for no load switching (AC-20A) above 690v. KG105 690 125 125 125 45 Panel Mount IP65 Size 1 = 64 x 64 Red / Yellow Padlock Handle - V840G/D C/W Off . On Escutcheon Plastic Enclosure IP65 Red / Yellow Padlock Handle - V840G
18 Code No. KG Main Switches - Base Mounted Padlockable with Extension Shafts Code No. Selection Data IEC 60947-3, EN 60947, VDE 0660 IEC 204, EN 60204, VDE 0113 Nominal Voltage Ui V Thermal Current IU / Ith A Enclosed Thermal Current Ithe A Operational Current AC21A Ie A Utilisation Category 3 x 380V / 440V AC-23A/B kW KG125 KG126 KG127 1000 (1) 125 100 125 45 KG100 690 100 80 100 37 KG80 690 80 63 80 30 KG64 KG64B 690 63 50 63 22 KG32 KG32B 690 32 32 32 11 KG20 KG20B 690 25 25 25 7,5 KG160 KG161 KG162 1000 (1) 160 140 160 55 KG250 KG251 KG252 1000(1) 250 250 250 90 KG315 KG316 KG317 1000 (1) 315 315 315 110 Switch Type KG41 KG41B 690 40 40 40 15 Product KG10B - KG100 = Base/DIN Mount Base Mounted with Door Clutch M280E 300mm Shaft Extension Padlock Device V845 Door Clutch M280E/EF P‘lockable HandleV840G/D Esc. plate OFF - ON 3 Pole KG10B K300*AUN0481 VE KG20B K300*AUN0481 VE KG32B K300*AUN0481 VE KG41B K300*AUN0481 VE KG64B K300*AUN0481 VE KG80 K300*AUN0481 VE KG100 K300*AUN0481 VE KG105 K300*AUN0481 VE KG126 K300*AUN0481 VE KG161 K300*AUN0481 VE KG211 K300*AUN0481 VE KG251 K300*AUN0481 VE KG316 K300*AUN0481 VE 6 Pole Isolator Panel Mounted Escutcheon plate OFF-ON KG20B K600*AU2103 E KG32B K600*AU2103 E KG41B K600*AU2103 E KG64B K600*AU2103 E KG80 K600*AU2103 E KG100 K600*AU2103 E KG126 K600*AU2103 E KG161 K600*AU2103 E 3 Pole Change Over Panel Mounted with OFF Escutcheon 1/0FF/2 6 Pole Isolator Aux. Contacts fitted on request 8 Pole Isolators and 4 Pole c/o also available KG10B - KG100 = Base/DIN Mount KG20B K900-620 E KG32B K900-620 E KG41B K900-620 E KG64B K900-620 E KG80 K900-620 E KG100 K900-620 E KG126 K900-620 E KG161 K900-620 E TERMINATION: KG10 ~ KG125, KG160, KG210 KG250 & KG315 Tunnel. KG126, KG161, KG211, KG251 & KG316 Lugs. KG127, KG162, KG212, KG252 & KG317 Tunnel & Lugs. Base Mounted with Door Clutch M280E 300mm Shaft Extension Padlock Device V840G/D Door Clutch M280E/EF P‘lockable HandleV840G/D Esc. plate OFF - ON 3 Pole + 1N/O 1 N/C aux. (N/O aux. early break) KG10B K302*AUN0483VE KG20B K302*AUN0483VE KG32B K302*AUN0483VE KG41B K302*AUN0483VE KG64B K302*AUN0483VE KG80 K302*AUN0483VE KG100 K302*AUN0483VE KG105 K302*AUN0483VE KG126 K302*AUN0483VE KG161 K302*AUN0483VE KG211 K302*AUN0483 VE KG251 K302*AUN0483VE KG316 K302*AUN0483VE KG10 KG10B 690 20 20 20 5,5 KG210 KG211 KG212 1000(1) 200 200 200 75 (1) Suitable for no load switching (AC-20A) above 690v. Door Clutch M280E/EF P‘lockable Handle V845 Esc. plate OFF - ON 3 Pole (without aux‘s) KG10B K300*AUN0482 VE KG20B K300*AUN0482 VE KG32B K300*AUN0482 VE KG41B K300*AUN0482 VE KG64B K300*AUN0482 VE KG80 K300*AUN0482 VE KG100 K300*AUN0482 VE KG105 K300*AUN0482 VE KG126 K300*AUN0482 VE KG161 K300*AUN0482 VE KG211 K300*AUN0482 VE KG251 K300*AUN0482 VE KG316 K300*AUN0482 VE Door Clutch M280E/EF P‘lockable HandleV840G/D Esc. plate OFF - ON 4 Pole KG10B K400*AUN0481VE KG20B K400*AUN0481VE KG32B K400*AUN0481VE KG41B K400*AUN0481VE KG64B K400*AUN0481VE KG80 K400*AUN0481VE KG100 K400*AUN0481VE KG105 K400*AUN0481VE KG126 K400*AUN0481VE KG161 K400*AUN0481VE KG211 K400*AUN0481VE KG251 K400*AUN0481VE KG316 K400*AUN0481VE KG105 690 125 100 125 45 VE-Mounting
19 Application Guide AS/NZS 947-3 3F Lockout Isolators Product Features M700 Door Interlock • Padlockable in ‘OFF’ only - safety requirement according to AS/NZS 947-3 • In ‘ON’ the door interlock is engaged - the cabinet cannot be opened • In ‘ON’ the door interlock can be defeated by using a tool - authorised entry only • The door interlock re-engages when the door is closed after authorised defeat in ‘ON’ • In ‘OFF’ and padlocked, the door interlock defeat is disabled - no access • When the door is opened the handle position is locked - assured alignment • Mechanical Position Indicator on the switch module - visible when the door is open • Internal Padlock Device on switch module • Robust, keyed, floating head on switch shaft KG Switch Disconnectors • 13/14mm contact gap. 690v - 1000v insulation • High AC3 and AC23 ratings • Large, finger proof IP20 box type terminals • Double break forced opening safety rated auxiliary contacts. Silver or Gold 1 to 6 N/O - N/C • Positive drive make and break main contacts. 3 to 8 poles OFF ON, 3 or 4 pole C/O • IEC 947-3 3F disconnector handle. Isolation is assured ‘OFF’ is ‘OFF’ General Features • Custom colours and engraving for escutcheon plates and header labels • Scratch-proof reverse engraving • IP65 dust and water protection • Robust, double insulated handle • Asymmetric shaft and interlock profiles ensure the handle position matches the switch position • Fixed length shaft ensures shaft must engage with the handle Get a Handle on Safety with your Eyes Closed Telephone now for a demonstration IEC 947-1 Equipment Suitable For Isolation - The Following Clauses Apply Clause 7.1.6 Additional constructional requirements for equipment suitable for isolation Clause 7.1.6.1 Additional constructional requirements Equipment suitable for isolation shall provide, in the open position (see 2.4.21) an isolation distance in accordance with the requirements necessary to satisfy the isolation function (see 7.2.3.1 and 7.2.2) (dielectric test) Indication of the position of the mains contacts shall be provided by one or more of the following means: (1) The position of the actuator (2) A separate mechanical indicator (3) Visibility of the moving contacts The effectiveness of each of the means of indication provided on the equipment and its mechanical strength shall be verified in accordance with clause 8.2.5 Clause 8.2.5 Verification of the effectiveness of indication of the main contact position of equipment suitable for isolation To verify the effectiveness of the indication of the main contact position, all means of indication of contact position shall continue to function correctly after the operational performance type tests, and special durability type tests (if performed). Switch Classifications All low voltage switches installed in Australia and New Zealand shall meet AS/NZS 60947 and carry the appropriate easily identifiable symbol depending on the switch classification. Switch A mechanical switching device capable of making and breaking currents under normal conditions, which may include specified overload conditions according to the duty, and abnormal circuit conditions such as short-ci cuit. (motor reversing switches, control switches, start delta switches, etc) Disconnector A mechanical switching device which in the open position, complies with the requirements specified for the isolating function (Off load isolator) Switch Disconnector A ‘Switch’ which in the open position, complies with the requirements specified for the isolating function (On load isolator) r Telephone 1800 567 948 for further technical information
20 Changeover Switches Base Mount & Enclosed VE2-Mounting VE-Mounting For Further Information Regarding The Range of Enclosed Isolators Refer to the Kraus & Naimer “Enclosed Switch Catalogue” on www.krausnaimer.com.au Enclosed- Plastic Product Base Mount Code No. Base Mount Code No. Base Mount Code No. 2 Pole Changeover Din Rail Mtg - MCB cut out Eng: Mains Off Gen KH32 T902*NZ0001 VE2 KH40 T902*NZ0001 VE2 KH63 T902*NZ0001 VE2 KH80 T902*NZ0001 VE2 3 Pole Changeover Din Rail Mtg - MCB cut out Eng: Mains Off Gen KG32A T903*NZ0001 VE2 KG41B T903*NZ0001 VE2 KG64B T903*NZ0001 VE2 KG80 T903*NZ0001 VE2 KG100 T903*NZ0001 VE2 KG32A T903*AUV0290 VE2 KG41B T903*AUV0290 VE2 KG64B T903*AUV0290 VE2 KG80 T903*AUV0290 VE2 KG100 T903*AUV0290 VE2 3 Pole Changeover Din Rail Mtg - MCB cut out Eng: Mains Off Aux KG32A T904*AUN0127 VE2 KG41B T904*AUN0127 VE2 KG64B T904*AUN0127 VE2 KG 80 T904*AUN0127 VE2 KG100 T904*AUN0127 VE2 4 Pole Changeover Din Rail Mtg - MCB cut out Eng: Mains Off Gen KG20B K950*AUN0125 VE KG32B K950*AUN0125 VE KG41B K950*AUN0125 VE KG64B K950*AUN0125 VE KG 80 K950*AUN0125 VE KG100 K950*AUN0125 VE KG126 K950*AUN0126 VE KG161 K950*AUN0126 VE 6KE252 K950*AUN0130 VE(250A) 6KE402 K950*AUN0130 VE(400A) 4 Pole Changeover (unenclosed) with M280E door clutch Eng: Mains Off Gen KG20B K900*AUV0291 VE KG32B K900*AUV0291 VE KG41B K900*AUV0291 VE KG64B K900*AUV0291 VE KG 80 K900*AUV0291 VE KG100 K900*AUV0291 VE KG126 K900*AUV0291 VE KG161 K900*AUV0291 VE 3 Pole changeover (unenclosed) with M280E door clutch Eng: Mains Off Aux KG20B K900*AUN0123 VE KG32B K900*AUN0123 VE KG41B K900*AUN0123 VE KG64B K900*AUN0123 VE KG 80 K900*AUN0123 VE KG100 K900*AUN0123 VE KG126 K900*AUN0124 VE KG161 K900*AUN0124 VE 3 Pole changeover (unenclosed) with M280E door clutch Eng: Mains Off Gen VE2-Mounting
21 Changeover Switches Base Mount & Enclosed For 3 Pole changeover KG20B - 190 x 100 x 90 - 6mm KG32B - 190 x 100 x 90 - 6mm KG41B - 250 x 145 x 100 - 16mm KG64B - 250 x 145 x 100 - 16mm KG KG80 - 280 x 190 x 130 - 35mm KG100 - 280 x 190 x 130 - 35mm KG126 - 560 x 380 x 180 - M10 (Lugs) - 95mm KG161 - 560 x 380 x 180 - M10 (Lugs) - 95mm For 4 Pole changeover KG20B - 190 x 190 x 130 - 6mm KG32B - 190 x 190 x 130 - 6mm KG41B - 280 x 190 x 130 - 16mm KG64B - 280 x 190 x 130 - 16mm KG 80 - 380 x 280 x 130 - 35mm KG100 - 380 x 280 x 130 - 35mm KG126 - 560 x 380 x 180 - M10 (Lugs) - 95mm KG161 - 560 x 380 x 180 - M10 (Lugs) - 95mm 6KE252 - 600 x 600 x 350 Metal - M10 (Lugs) - 150mm 6KE402 - 800 x 600 x 400 Metal - M10 (Lugs) - 240mm Enclosure for Domestic / Commercial Installations Suitable for VE2 2 & 3 Pole Changeover 64CC6 To 63 Amp IP40 Suitable for VE2 2 Pole Changeover 6FKV To 40 Amp IP65 64CC6 6FKV 8 Free Phone 0800 736 522 Order Code Example: KH20 T922*NZ0001 VE2 Surface Mounting Enclosure For Domestic / Commercial Installations Max 40 amps Suitable for Two Pole Changeover Switches with Off to 40 amp IP40 Suitable for Two Pole Changeover Switches with Off to 40 amp IP65 9SE6P 9KMB 40.00 55.00 Ith2 Amps 20 32 40 63 80 25 32 40 63 80 100 Max Cable 10 10 10 35 35 6 6 16 16 50 50 92.30 147.00 165.70 217.90 272.60 Din rail Mount with MCB Front Plate (45mm) Knockout with Standard Handle 1 Pole Mains/2 Pole Generator T922*NZ0002 VE2 T922*NZ0002 VE2 T922*NZ0002 VE2 T922*NZ0002 VE2 T922*NZ0002 VE2 Code No KH20 KH32 KH40 KH63 KH80 KG20A KG32A KG41B KG64B KG80 KG100 2 Pole Mains/2 Pole Generator T902*NZ0001 VE2 T902*NZ0001 VE2 T902*NZ0001 VE2 T902*NZ0001 VE2 T902*NZ0001 VE2 92.30 147.00 165.70 217.90 272.60 3 Pole Mains/4 Pole Generator T934*NZ0001 VE2 T934*NZ0001 VE2 T934*NZ0001 VE2 T934*NZ0001 VE2 T934*NZ0001 VE2 T934*NZ0001 VE2 187.90 230.40 296.20 364.60 548.10 674.90 3 Pole & thru N Mains/4 Pole Gen T944*NZ0001 VE2 T944*NZ0001 VE2 T944*NZ0001 VE2 T944*NZ0001 VE2 T944*NZ0001 VE2 T944*NZ0001 VE2 211.50 259.00 328.50 403.20 597.80 742.10 Ith2 Amps 20 32 40 63 80 25 32 40 63 80 100 125 125 160 Max Cable 10 10 10 35 35 6 6 16 16 50 50 50 M10 lug M10 lug 142.30 199.50 218.20 270.40 325.10 Base Mount with Door Clutch IP40 1 Pole Mains/2 Pole Generator T922*NZ0003 VE T922*NZ0003 VE T922*NZ0003 VE T922*NZ0003 VE T922*NZ0003 VE Code No KH20 KH32 KH40 KH63 KH80 KG20A KG32A KG41B KG64B KG80 KG100 KG105 KG126 KG161 2 Pole Mains/2 Pole Generator T902*NZ0008 VE T902*NZ0008 VE T902*NZ0008 VE T902*NZ0008 VE T902*NZ0008 VE 142.30 199.50 218.20 270.40 325.10 3 Pole Mains/4 Pole Generator T934*NZ0003 VE T934*NZ0003 VE T934*NZ0003 VE T934*NZ0003 VE T934*NZ0003 VE T934*NZ0003 VE T934*NZ0003 VE T934*NZ0001 VE T934*NZ0001 VE 238.10 280.40 355.00 423.40 603.80 730.60 935.80 1000.10 1291.10 3 Pole & thru N Mains/4 Pole Gen T944*NZ0003 VE T944*NZ0003 VE T944*NZ0003 VE T944*NZ0003 VE T944*NZ0003 VE T944*NZ0003 VE T944*NZ0003 VE T944*NZ0001 VE T944*NZ0001 VE 261.70 309.00 387.30 467.00 653.50 797.80 1034.10 1124.40 1457.80 Product Base Mount Code No. Base Mount Code No. Enclosure & cable size ENCL: 6AE Mains Off Gen Metal Enclosure C/W Right Angle Drive For Further Information Regarding The Range of Enclosed Isolators Refer to the Kraus & Naimer “Enclosed Switch Catalogue” on www.krausnaimer.com.au 6AE-Enclosure Mains Off Gen Metal Enclosure Enclosed Code No. KG20B K950*AUN0119*6FE KG32B K950*AUN0119*6FE KG41B K950*AUN0120*6FE KG64B K950*AUN0120*6FE KG 80 K950*AUN0121*6FE KG100 K950*AUN0121*6FE KG126 K950*AUN0122*6FE KG161 K950*AUN0122*6FE 6KE252 K950*AUN0128*6AE(250A) * 6KE402 K950*AUN0129*6IP (400A) * 4 Pole Changeover Enclosed - Plastic IP65/Metal IP65 Eng: Mains Off Gen KG20B K900*AUV0290*KL12 KG32B K900*AUV0290*KL12 KG41B K900*AUV0290*KL12 KG64B K900*AUV0290*KL12 KG 80 K900*AUV0290*6FE KG100 K900*AUV0290*6FE KG126 K900*AUV0290*6FE KG161 K900*AUV0290*6FE 3 Pole Changeover Enclosed - Plastic IP65 Eng: Mains Off Aux KG20B K900*AUN0115*KL12 KG32B K900*AUN0115*KL12 KG41B K900*AUN0116*KL12 KG64B K900*AUN0116*KL12 KG 80 K900*AUN0117*6FE KG100 K900*AUN0117*6FE KG126 K900*AUN0118*6FE KG161 K900*AUN0118*6FE 3 Pole Changeover Enclosed - Plastic IP65 Eng: Mains Off Gen
22 S0 V760/A.E Keylocks Code Mounting Units Code Mounting Units Code Optional Extras E Panel mount 2 or 4 screw Panel mount 2 or 4 screw EFA IP65 VE Base mounting 4 screw mount VE1 Base mount DIN rail VE2 Base mount DIN rail with MCB cut out ER Double end mount 4 screw fixing VE1E Double end mount for fixing of plate with DIN mounting IP66 Single hole without plate 16/22mm FSI 22/30mm FT1 IP66 Single hole square plate 16/22mm FS2 22/30mm FT2 Next size up handle and plate EG Single hole with plate 16/22mm Rectangle 30 x 39 FS4 Single hole with plate 16/22mm Rectangle 48 x 59 FT6 Single hole with plate 16/22mm Rectangle 64 x 78 FH4 Header 2 Lines PRC Header 3 Lines PRA Direct drive operator V750/A9 For base mounting IP66 For single hole 22mm V750D/3 Standard K&N Key Separate Drive Key Lock Programmable locking V760/A.E positions using Strebor barrel Right Angle Drive K3 M330/A K3 M330/B Terminal Covers 3 main contacts KG 20 - KG 100 M160 / 3 KG 126 / KG 161 M160 / 33 KG 251 / KG 316 M160 / 4 4 main contacts KG 20 - KG 100 M160 / 43 KG 126 / KG 161 M160 / 43 KG 251 / KG 316 M160 / 41 Separate Drive Key Lock Programmable locking V760/A positions for: Lockwood 5-6 pin barrels C4 (201). Bi - Lock.(specify) Includes: Kraus & Naimer Pty. Ltd. standard barrel:- 6S1 V760 S (Lockwood type). V755/ 6CL Direct Drive Key Operator 6S0LW V755/A Nominate key barrel:- 570 Lockwood, Bi-Lock,Lock Focus, KabaQuattro, Efco, Schlage, CL, etc..... Customised key systems:- Key Indication, cylinder removable from front (RL), Electronic key interlocks etc. Nominate Mounting:- Panel mount, Wall Plate mounting, enclosed (plastic,s/steel etc), V750D/ VE21 Direct Drive Key Operator Mounted in a IP66 Hinged / Flip Lid Enclosure Optional Extras 18 Keylocks Code Direct drive operator Mounting Units Code V750/A9 Free Phone 0800 736 522 9 201/5P V750D V750D/2 V750D/3 V765 V760/A V760/AE Ronis (601) S00 V750 S2 K&N (KN101) S0C V750 S2 For base mounting VE21 Separate drive key lock Standard K&N key Separate drive key lock Yale type key With half-cylinder lock 5 pin Barrel Spare Keys Standard K&N Spare Keys Security For single hole 22mm Standard K&N key For single hole 16/22mm Standard K&N key E Panel mount 2 or 4 screw Panel mount 2 or 4 screw. IP65 Base mounting 4 screw mount Base mount DIN rail Base mount DIN rail with MCB cut out Double end mount for fixing of esc. plate with DIN mounting base Double end mount for fixing of esc. plate with screw mounting base Single hole without esc plate 16/22mm 22/30mm Single hole square plate 16/22mm 22/30mm Next size up handle and plate EG Single hole with plate 16/22mm Rectangle 30 x 39 Single hole with plate 16/22mm Rectangle 48 x 59 Single hole with plate 16/22mm Rectangle 64 x 78 FS4 FT6 FH4 VE1 VE1E ER FS1 FT1 FS2 FT2 Special Engraving $14.90 V750D/1 For single hole 16/22mm Security key Kaba EG0031 AUTO SELECT
23 Padlock Code Door Clutch & Shaft Extensions Code Optional Extras The padlock is an integral V840A part of the switch handle Locking handle for V840B DIN cutout handles For a padlocks V845 Padlock with integral V840D flat or raised handle - 2 padlock Padlock with integral V840G/B flat or raised handle - 3 padlock Padlock with integral V840G flat or raised handle - 4 padlock Padlock device V850 Shaft locking device V840VE Heavy Duty 6SS V840 Stainless Steel Lock-out safety device Clip on aux contacts - base mount KO-H010/A11-VE for KG20 -KG32 K1-H010/A11-VE for KG41 - KG64 Clip on aux contacts - panel mount KO-H010/A11-E for KG20 -KG32 K1-H010/A11-E for KG41 - KG64 Single hole 22mm door clutch M295A Single hole 22mm door V840E clutch and locking handle IP66 Single hole 22mm door V840G/B clutch and locking handle IP66 Single hole 22mm door V840G clutch and locking handle IP66 Single hole 22mm door V845 clutch and locking handle Door clutch with M280E shaft extension Interlocked or Non Interlocked Available IP66/67 Single hole mounting M800 with integrated door clutch *Override fuction in On-Position Door clutch for misaligned doors with locking handle M700 Note: Knowledgeable personnel using a simple tool are able to defeat the interlock Refer to Page 19 Shaft extentions M004D asymmetric profile Shaft extentions L100A/M004E square profile
24 Special Drive Options & Enclosures G800/A G800/B G900/B GK PK DIP Exd 6S Special Drives Optional Code No. Description 15 l Off PK1) Return PK1) ll Off GK1) Return GK1) urn (Red) GK1) Switch turn Rev 2 0 Switch turn *E 0 960 Finish:- Bead Blast or Food Industry. (N0 4) Options:- Rain Hood. Hinge Door. Variations on request:- Stop / Start Pushbuton. Control & Changeover Switches. Selection of auxiliary contacts. Stainless Steel Enclosures Marine Grade 316 208H x 113W x 96D 240H x 140W x 120D 350H x 230W x 170D 500H x 320W x 175D 710H x 320W x 175D C/W rain hood (Other sizes available on request) HAZARDOUS AREAS Dust Ignition Proof Flame Proof Plastic Enclosures for Drives Switch length 4 stages. Various sizes available on request. Aluminium Enclosures for Drives Switch length 4 stages. Various sizes available on request. Rope Operator Heavy duty for GK / PK or 6CL 56 series enclosures. Drive Only Also Available in 6CL 56 Plastic Enclosure Limit Switch Heavy duty roller & actuator for spring return or stepping applications. E Panel Mount PK Plastic Enclosure GK Aluminium Enclosure Also Available in 6CL 56 Plastic Enclosure. Heavy Duty Drive Create your own handle/drive unit and weld it onto the removable plate. Long rods, T-bars, etc. E Panel Mount, PK Plastic Encl. GK Aluminium Enclosure
25 KS KS PF 6 CL 56/98 6 CL 56/98-4 6 CL 56/195 6FE B85AG 6FE C65AG 6FE C85AG 6FE D85AG 6FE M95AG 6AE 1033 6AE 1385 6AE 1338 Enclosure Information The following options can be included by substituting suffix code “E” for the optional code number.. PF, KS, KL, 6CL... Note: KG enclosed isolators listed complete on page 17 Example: 3pole 20Amp Off/On Switch CA 10 A292-621 PF Enclosed with Padlockabe handle V840G Enclosures Code No. Description Standard Enclosures CG 4 & CA 4 Switches Material - Very high UV resistance - High chemical resistance Dimensions mm 1 stage - 90L x 70W x 60H 2 stage - 90L x 70W x 72.5H Standard without Cover Interlock Very high UV resistance Excellent chemical resistance Industrial Enclosure IP66 Dimensions mm - 101L x 101W x 91H /98 series - 198L x 101W x 91H /195 series Chemical resistant orange available on request. (Nominate entries prefered). General Purpose ABS Enclosures Excellent Chemical resistance IP67. 6FE B85AG - 110H x 80W x 85D 6FE C65AG - 140H x 80W x 65D 6FE C85AG - 140H x 80W x 85D 6FE D85AG - 170H x 60W x 85D 6FE M95AG - 230H x 140W x 95D Polycarbonate Enclosures IP67 6FEC - 190H x 190W x 130D 6FEC - 190H x 190W x 180D 6FEC - 280H x 190W x 130D 6FEC - 280H x 190W x 180D 6FEC - 280H x 280W x 130D 6FEC - 380H x 280W x 130D 6FEC - 380H x 280W x 180D 6FEC - 560H x 380W x 180D 6FEC - 560H x 380W x 230D Metal Enclosures IP67 Switches mounted to gear tray with door interlock. 6AE 1033/300 x 300 x 210 6AE 1385/380 x 380 x 250 6AE 1338/600 x 380 x 350 Additional metal enclosures available FOR FURTHER INFORMATION ON LARGER ENCLOSURES PLEASE CALL YOUR NEAREST BRANCH KS enclosure 6 CL 56/98 enclosure 6 FE enclosure PF enclosure AE enclosure 6 FEC enclosure Flip Lid
1 26 NEW from Kraus and Naimer (Australia) Motor isolators 3, 4 and 6 pole (c/w aux contacts) supplied in glass reinforced plastic IP66 enclosures. Why use the GRP type of enclosure 1. Is highly tolerant of the most aggressive of environments. Can be installed in marine, chemical and direct sunlight areas. Has high resistance to ultraviolet light. 2. GRP enclosures are resistant to high impacts. 3. GRP is non conductive, inert and non sparking. 4 Easy to drill or punch entries for installing electrical operators e.g. pushbutton, pilot lights, etc. 5. Low Maintenance. Sydney Phone: 1800 567 948 Email: sales-au@krausnaimer.com Melbourne Phone: 1800 567 948 Email: sales-au@krausnaimer.com Brisbane Phone: 1800 567 948 Email: sales-au@krausnaimer.com Adelaide Phone: +61 8 8371 1443 Email: salessa@krausnaimer.com Website: www.krausnaimer.com.au Available in various sizes, either screw lid or hinged. Options include: No entries, punched entries, IP66 metal glands, EMC glands + RFI kit.
www.krausnaimer.comRkJQdWJsaXNoZXIy MTAxNzE=